Installation; Mechanical Assembly - Festo DNCE LAS Série Notice D'utilisation

Le vérin électrique
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 63
DNCE−...−LAS
5

Installation

Mechanical assembly

Fitting in a vertical or sloping position
Warning
Uncontrolled moving masses can cause injury to people (danger of fingers
being squashed) or damage to property.
S Check whether additional external safety measures are required to prevent
the working load from sliding down.
The DNCE−LAS has no self−locking.
With all applications
Note
The possible dynamics and accuracy of the DNCE−LAS may be reduced
depending on the fitting (stiffness and temperature stress).
S Make sure that the device is fitted free of mechanical stress and distortion
(e. g. by fastening with a fixed bearing and a movable bearing).
S Avoid an accumulation of heat. A high packing density or tight installation
situations cause an accumulation of heat.
S Make sure that the mechanical components (incl. base) are not fitted too
stiffly.
Fasten the DNCE−LAS.
S
Please select the appropriate accessories
S
from our catalogue
www.festo.com/catalogue
Note the maximum permitted tightening
S
torque for the fastening screws of 5 Nm
(M6).
Tighten the screws evenly.
S
28
Fig. 2
Festo DNCE−...−LAS 1003b English

Publicité

Table des Matières
loading

Table des Matières