4.2 Technical specification
Name
Article no.:
Construction:
Material:
Power:
Temperature range:
Cooling medium:
Capacity:
Dimensions:
Weight:
Equipment:
We reserve the right to make technical changes!
* delivered without GN boxes
5. Installation and operation
5.1 Safety instructions
WARNING! Risk of electric shock!
The device must only be connected to a properly installed single socket with
protective contact.
Never remove the power cable by pulling the cable itself; always grab the plug
housing.
•
Never allow the power cable to come into contact with heat sources or sharp edges.
The power cable should not hang over the side of the working surface. Ensure that no
one can step on or trip over the cable.
•
The power cable must not be folded, bent or tangled, and must always remain fully
unrolled.
•
Never place the device or other objects on the power cable.
- 24 -
Ventilated saladette 1/1 GN with 1 door
and evaporator packed in foam
for 3 x 1/3 GN, 2 x ½ GN or 1 x 1/1 GN,
GN boxes 150 mm deep *,
1 door, changeable hinge side
housing: nickel-chrome steel;
work surface: polyetylene
0.23 kW / 230-240 V 50 Hz
0 ° C – 10 ° C
R134a / 150 g
width 438 x depth 700 x height 882 mm
2 partitions as shelves for GN boxes:
length 537 mm, width 35 mm;
1 grid 1/1 GN, width 335 x depth 570 mm
200270
140 litres
103 kg