USE
A
B
Key
Function
Switches the blower motor on and off at the
A
latest selected speed
Decreases the vent speed.
B
Increases the vent speed.
C
By pressing this key it is possible to activate
D
the intensive speed from any previously se-
lected speed. The intensive speed can be acti-
vated even when the motor is OFF. This speed
has been timed at 10 minutes. After that time
the system activates automatically the latest
selected speed. This function is recommended
for cooking condition where vapors and odors
need to be eliminated immediately and quickly.
E
By pressing this key it is possible to set up the
motor to a suction speed at 60 CFM lasting 10
minutes every hour. After this the motor
switches off automatically.
When the filter saturation is going on it is pos-
sible to reset the alarm by pressing this key for
about 3 seconds. The indication is visible only
when the motor is off.
By pressing this key it is possible to set the
F
delayed shutdown of the appliance to 30 min-
utes. This function is suitable for a complete
elimination of the residual odors. It can be ac-
tivated at any position, and it is deactivated by
pressing the key again or by switching off the
motor.
Turns light on and off .
G
Turns light on and off at reduced intensity.
H
EN
C
D
Control board
E
Display
Indicates the selected speed.
HI appears. The spot down on the right side
flashes once a second.
Indicates the 24-function. The spot down on
the right side flashes and the motor is on.
Once the process is finished the previous indi-
cation disappears:
FF
Indicates that the metal grease filters
saturation alarm has been triggered, and
the filters need to be washed. The alarm
is triggered after 100 working hours.
EF Indicates that the charcoal filter satura-
tion alarm has been triggered, and the fil-
ter has to be replaced; the metal grease
filters must also be washed. The charcoal
filter is triggered after 200 working hours.
Indicates both the selected speed of the hood
and the time left before the hood shutdown.
The spot down on the right side flashes alter-
nately displaying the speed and shutdown time.
F
G
H
1
11