ELECTRICAL CONNECTION
Remove the wiring box cover by removing the two screw.
Insert the cable of the remote blower into the knockout hole
of the rangehood. Insert the power supply cable into the hole
of the rangehood. Connect the green ground wire from the
supply to the ground screw. Connect the green ground wire
from the remote blower to the other green gfround screw.
Exterior blower motor wiring:
• Connect the remote blower motor wire to the blue Range-
hood wire with a twist-on connector.
• Connect the other remote blower motor wire to brown
Rangehood wire with a twist-on connector.
120-volt supply wiring:
• Connect 120-volt black supply wire to black Rangehood
wire with a twist-on connector.
• Connect 120-volt supply white wire with to white Range-
hood wire with a twist-on connector.
Replace the wiring box cover Tighten the screw securely.
Reinstall the baffle filters. Reconnect the power.
Chimney assembly
Upper exhaust Chimney
• Slightly widen the two sides of the upper flue and hook
them behind the brackets 7.2.1, making sure that they are
well seated.
• Secure the sides to the brackets using the 4 screws 12c
supplied.
Lower exhaust Chimney
• Slightly widen the two sides of the chimney and hook
them between the upper chimney and the wall, making
sure that they are well seated.
• Fix the lower part laterally to the hood body using the 2
screws 12c supplied.
Kitchen rail assembly
• Fix rails 3 to the bottom part of the Hood using the 12c
screws (2.9 x 9.5) supplied with the appliance.
EN
blue wires
(from Rangehood)
browm wires
(from Rangehood)
black wires
(from blower)
white wires
(from blower)
exterior
blower
wiring
green
ground
screw
2.1
2
2.2
3
Rangehood
wiring
black
wires
white
wires
twist-on
connector
power
supply
cable
green
ground
wires
7.2.1
12c
12c
12c
1
10
0