How do I locate faults?
The recommended tool for locating faults is the PATURA fence compass. This combined voltage
and current meter allows you to rapidly locate sources of current leakage. Alternatively, use a
PATURA DVM or fence tester. Use cut-out switches to turn off the power to different sections of
the electric fence. If the voltage on the fence increases when a section of the electric fence is
turned off, then investigate that section for possible faults.
There are no lights flashing on the energiser.
Check the power supply. Ensure that the power is switched on. If the energiser still does not
operate, request your PATURA service agent to check the energiser.

Servicing

This energiser contains no user serviceable parts. It must be returned to a PATURA-appointed
service agent for repair.

Product Specifications

Power Supply
Power Consumption
Fast pulse
Slow pulse
Output voltage
No Load
500 ohms
Max. Output energy
Stored energy
Dimensions (WxHxD)
Weight
P20
9 V Battery *
* Instead of a 9 V battery a 12 V battery can be used.
In this case the battery control function is not available.
22 mA
14 mA
9.6 kV
2.0 kV
0.14 J at 2000 ohms
0.20 J
160x320x235 mm
1.85 kg
- 42 -
P40
9 V Battery *
32 mA
20 mA
9.8 kV
2.6 kV
0.21 J at 2000 ohms
0.31 J
160x320x235 mm
1.85 kg
P60
9 V Battery *
48 mA
30 mA
10.3 kV
2.9 kV
0.28 J at 2000 ohms
0.44 J
160x320x235 mm
1.85 kg