PROGRAMMING/ADDING A NEW (INDIVIDUAL, GROUP, OR MAIN) CONTROL POINT
4
4.1- Open the memory of the receiver from the
individual control transmitter:
- Press the "PROG" button of the transmitter for about
3 seconds. The motor will run for 0.5 second in one
direction and then in the other.
4.2- Confirm the operation from the new transmitter
you wish to add:
Press the "PROG" button of the transmitter for 1 second.
The motor will run for 0.5 second in one direction and then
in the other.
The operation is completed.
- For group controls, repeat operations 4.1 and 4.2 for each motor in the group.
- For general controls, repeat operations 4.1 and 4.2 for each motor in the installation.
- To delete an transmitter from the memory of a motor, perform operations 4.1 with a programmed transmitter,
then perform the operation 4.2 with the transmitter to be deleted.
PROGRAMMING A SENSOR
5
5.1- Open the memory of the motor from the individual
control transmitter:
- Press the "PROG" button of the transmitter for about
3 seconds. The motor will run for 0.5 second in one
direction and then in the other.
5.2- Confirm the operation from the sensor you wish
to add:
- Press the "PROG" button of the sensor less than 1
second. The motor will run for 0.5 second in one direction
and then in the other. The operation is completed.
For group controls, repeat operations 5.1 and 5.2 for each motor in the group.
Recommendations when using a sensor: If the Wind sensor on an installation is changed or deleted, it
is important to delete it from the memory of all the motors in which it was programmed: perform operation
5.1 with a programmed transmitter, then perform the operation 5.2 with the sensor to be deleted.
RECORDING / CONTROLING / DELETING INTERMEDIATE POSITION
6
Recording :
1- Move the motor to the wished
position.
2- Press 5 seconds on the STOP
button. The motor will run for
0.5 second in one direction,
then in the other direction.
Deleting: Position the motor on the intermediate position. Press 5 seconds on the "Stop" button. The motor
will run for 0.5 second in one direction, then in the other direction. The intermediate position is deleted.
1
1
1
2
+
5 s
PROG ≥ 3 s
2
PROG < 1 s
PROG ≥ 3 s
2
PROG < 1 s
Control :
- Press
the
« STOP » button
for 0.5 second.
The motor runs to
the intermediate
position.
>>
>>
>>
>>
EN
5/8