SECTION 5
5.3 Gas Manifold Pressure Switches
5.3.1 Pressure Switch Adjustment Procedure
5.3.2 Gas Manifold with Non-adjustable Pressure Switches (reference)
Newer EPP-200 consoles are equipped with nonadjustable preset gas
manifold pressure switches.
Older ESP-200 consoles have adjustable pressure switches.
Both type switches are preset for:
• 17 psig (1.2 bar), shield and start gas switches
• 22 psig (1.5 bar), cut gas switch
1. Turn main power switch OFF OFF.
2.
Remove right side panel
3.
Turn wheel:
• Counterclockwise to increase pressure
• Clockwise to decrease pressure
4.
Replace panel.
5.
Resume operation.
27
MAINTENANCE