2. Connect the hose from the dust extractor to the
propane tank.
3. Make sure the couplers are in line and tightly
screwed together by hand. Never complete the
connection of the tank to the machine by using a
tool. If this is not done properly, fuel will not pass
through to the regulator.
4. Do a soap test by pressurizing all LPG lines. See
examine the propane/LPG tank and lines on page
14 .
To start and stop
CAUTION: Before starting the dust extractor,
make sure that the inlet valve is open and
that the clutch is disengaged.
1. Open the propane tank valve by turning
counterclockwise.
2. Make sure the clutch switch is in "OFF" position.
LAMBDA
SENSOR
8
To
COUPLING
1
0
START
OFF
ON
FUSE
20A
3. Make sure that the throttle handle is on lowest
speed.
4. Start the engine with the key switch, turn and hold
the key to "START" and release when the engine is
running. The key will now point at "1".
LAMBDA
SENSOR
5. When the engine has warmed up and is running at
idle, engage the clutch. Turn the switch to "ON".
LAMBDA
SENSOR
6. Dust-laden air is then sucked through the inlet valve
via the suction hose.
7. Push the throttle handle to increase the RPM.
8. To stop the dust extractor, turn the gas off at the
service valve and allow propane in the fuel lines to
be consumed. Repeat the steps in reverse order.
To restart the product when the
emission sensor indicator is lit
WARNING: The dust extractor will shut
down when the CO emission levels are too
high in the working area.
COUPLING
1
0
START
OFF
ON
FUSE
20A
COUPLING
1
0
START
OFF
ON
FUSE
20A
570 - 003 - 07.06.2018