Part no:
590435901
To examine the wires
Check all wire connections if the product doesn't start.
1. Remove the propane tank.
2. Open the battery hatch.
3. Examine if any connections are loose, damaged or
unconnected.
4. Repair or replace wires as needed.
To examine the propane/LPG tank and lines
CAUTION: All products are equipped with
tamperproof fuel systems. If a fuel problem
exists, contact an authorized service center.
Note: Make sure to weigh the tank as being filled and
never overfill the LPG tank. The LPG tank is designed to
hold a maximum of 20 pounds of propane. The gross
weight of a full tank should not exceed 48 pounds.
Every tank has been pressure and leak tested.
However, every time a tank is filled and/or connected to
the product:
Warranty
All Pullman Ermator devices and accessories have a 12-
month factory warranty for material and manufacturing
defects. Pullman Ermator will grant an extended
warranty to 24 months against defects caused by faulty
materials and workmanship when a warranty form is
completed and returned to Pullman Ermator within 7
days from the delivery date of the machine to the end
user.
Do not attempt to repair the suction apparatus without
the consent of the manufacturer. The warranty does not
cover defects which are the result of normal wear and
tear, negligence, defective use, unauthorized repair or
the suction apparatus being connected to the incorrect
voltage. In the event of any complaint, the suction
apparatus or an agreed part of it must be returned to us
or our authorized representative for warranty
examination and for any warranty repair or replacement.
14
Description
HEPA FILTER T-LINE
WARRANTY
T 8600 Propane
2
1. Make sure the couplers are in line and tightly
screwed together by hand, never complete the
connection of the tank to the machine by using a
tool. If this is not done properly, fuel will not pass
through to the regulator.
2. Carry out a soap test by pressurizing all LPG lines.
3. Spray every inch of line and all connections. If you
find a leak, contact an authorized service center.
When operating the dust extractor:
If the tank has been overfilled, a frost forming
will appear on the LPG lines or on the regulator.
4. Turn off the dust extractor otherwise it will be
damaged.
5. The excess propane in the tank must be ventilated in
a safe manner, see
6. In some cases, the regulator must defrost before
restarting the dust extractor.
S 36 Propane
N/A
SAFETY on page 5 .
570 - 003 - 07.06.2018