2) When replacing a lamp, carefully remove the old
lamp from the lamp support and pull off the lamp-
holder.
3) Place the lampholder on the pin base of the new
lamp and carefully insert the lamp into the lamp
support.
4) Tightly close the cover of the lamp compartment
with the two screws.
5 Mounting
Use a support for projectors or a sturdy mounting
screw to fix the unit via its mounting bracket (4) to the
desired location (crossbar of a lighting stand or hori-
zontal T-bar). For aligning the unit, release the set-
screws (5), adjust the desired inclination of the unit
and retighten the setscrews.
Important!
To prevent heat accumulation within the unit, the
mounting location must be selected in such a way
that a sufficient air circulation is ensured during op-
eration. The air vents of the housing must not be
covered (e. g. by curtains, etc.).
6 Operation
Connect the supplied mains cable with cold appliance
inline jack to the cold appliance chassis plug (1), then
connect the mains plug to a socket (230 V~/50 Hz). As
soon as the unit is connected to the power supply, it is
switched on and immediately ready for operation. For
switching off the unit, disconnect the mains plug from
the socket.
For a more convenient operation, it is recom-
mended to connect the unit to a mains socket which
can be switched on and off via a light switch.
6.1 Music control
For controlling the scanner via the integrated micro-
phone, adjust the volume on the music system in such
a way that the moving light beams reproduce the
dynamic power of the music in an optimum way. In
music intervals or with the music system switched off,
the patterns (gobos) and the rotation of the mirror are
controlled at random.
7 Specifications
Power supply: . . . . . . 230 V~/50 Hz
Power consumption: . 200 VA
Lamp: . . . . . . . . . . . . 1 halogen lamp (15 V/150 W),
Dimensions
(without mounting bracket)
LE-560: . . . . . . . . . 277 x 145 x 219 mm
LE-570: . . . . . . . . . 312 x 145 x 184 mm
Weight
LE-560: . . . . . . . . . 5.2 kg
LE-570: . . . . . . . . . 6.5 kg
According to the manufacturer.
Subject to technical change.
lamp base GZ 6.35
GB