Attention: 
Hoses and ductwork, must be ground connected (PE) , to 
avoid electro‐static charging, which could cause ignition‐
sparks.  
(JET Dust Collection Grounding Kit, Article Number: JW1053). 
 
5.4 Mains connection 
Mains connection and any extension cords used must comply 
with applicable regulations. 
The mains voltage must comply with the information on the 
machine licence plate.  
The mains connection must have a 16 A surge‐proof fuse. 
Only use power cords marked H07RN‐F 
Connections and repairs to the electrical equipment may only 
be carried out by qualified electricians.  
 
6.  Machine operation 
You can start and stop the machine with the magnetic switch 
(R, Fig 13).  
Attention: 
(400V version) if the direction of rotation is not correct, the 
phase converter inside the CEE Euro plug (T) must be pushed 
in and turned 180°. 
(See rotation arrow on machine for correct rotation) 
Fig 12 
Fig 13 
 
 
 
 
7. Maintenance and inspection 
General notes: 
Maintenance, cleaning and repair work may only be carried 
out after the machine is protected against accidental starting 
by pulling the mains plug. 
Inspect the proper function of the dust collection system 
daily. 
Clean the unit regularly. 
Defective safety devices must be replaced immediately. 
Repair and maintenance work on the electrical system may 
 
only be carried out by a qualified electrician. 
7.1 Cleaning Filter 
The filter must be cleaned when the air flow reduces, and 
before changing the collecting bag. 
Shake the filter bag whenever it is clogged and before each 
collector bag change. 
During the cleaning of the filter bag it's necessary to use a 
mask (mask with filtration). 
7.2 Changing collector bag 
Always disconnect the dust collector from the power source 
(unplug) before servicing or changing filter. 
During the changing or cleaning of the collector bag it's 
necessary to use a mask (mask with filtration). 
 
8. Trouble shooting 
 
Unit doesn't start 
*No electricity‐ 
check mains and fuse. 
*Defective switch, motor or cord‐ 
consult an electrician. 
 
Air flow too weak 
*Clogged filter‐ 
clean filter. 
*Collection bag is full‐ 
change the bag. 
*Wrong motor rotating direction (400V version)‐ 
change direction (see chapter 6). 
 
9. Environmental protection 
Protect the environment. 
Your appliance contains valuable materials which can be 
recovered or recycled. Please leave it at a specialized 
institution. 
 
 
This symbol indicates separate collection for electrical and 
electronic equipment required under the WEEE Directive 
(Directive 2012/19/EC) and is effective only within the 
European Union. 
 
 

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dc-1200-t

Table des Matières