Read and understand the entire instruction manual before
attempting assembly or operation of the dust collector.
Keep this operating instruction close by the product,
protected from dirt and humidity, and pass it over to the new
owner if you part with the tool.
No changes to the dust collector may be made.
Daily inspect the function and existence of the safety
appliances before you start the unit.
Do not attempt operation in this case, protect the dust
collector by unplugging the power cord.
Always wear the approved working outfit:
‐ safety goggles
‐ ear protection
‐ dust protection
During the changing or cleaning of the filters it's necessary to
use a mask (mask with filtration).
Always disconnect the dust collector from the power source
(unplug) before servicing or changing filters.
Wait until the impeller has stopped completely.
Never reach into the machine while it is operating or running
down.
To reduce the risk of injury from moving parts, always keep
inlet port covered with the guard provided.
Hoses or ductwork must be connected before switching on
the dust‐collector.
Filter and collection bag must be installed and in proper
condition, before switching on the dust‐collector
Make sure that the power cord does not impede work and
cause people to trip.
Do not operate the machine under the influence of drugs,
alcohol or any medication. Be aware that medication can
change your behaviour. ´
Keep children and visitors a safe distance from the work area.
Never leave a running machine unattended. Before you leave
the workplace switch off the unit.
Do not operate the electric tool near inflammable liquids or
gases.
Observe the fire fighting and fire alert options, for example
the fire extinguisher operation and place.
Do not use the dust collector in a dump environment and do
not expose it to rain.
Do not use this equipment to filter volatile fumes or smoke.
Wood dust is explosive and can also represent a risk to health.
Dust form some tropical woods in particular, and from
hardwoods like beach and oak, is classified as a carcinogenic
substance.
Do not stand on the machine.
Connection and repair work on the electrical installation may
be carried out by a qualified electrician only.
Replace a damaged filter immediately.
Replace a damaged collection bag immediately.
Have a damaged or worn power cord replaced immediately.
3.3 Remaining hazards
When using the machine according to regulations some
remaining hazards may still exist.
Dust can cause injuries.
The use of incorrect mains supply or a damaged power cord
can lead to injuries caused by electricity.
Danger of explosion if not properly grounded.
4. Machine Specifications
4.1 Technical data
Dust inlet
Air flow Ø125
Vacuum pressure
Collector bag capacity
Collector bag diameter
Mains
Input power
Reference current
Extension cord (H07RN‐F)
Installation fuse protection
Protection class
Ø125mm (2xØ100mm)
1200 m³/h
1880 Pa
150 L
500 mm
1~230V, PE, 50Hz
1,5kW (2HP) S1
7.3 A
3x1,5 mm²
16A
I