Remaining Hazards; Machine Specifications; Technical Data - Jet DC-1200-M Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

 
Read and understand the entire instruction manual before 
attempting assembly or operation of the dust collector. 
 
Keep this operating instruction close by the product, 
protected from dirt and humidity, and pass it over to the new 
owner if you part with the tool. 
No changes to the dust collector may be made. 
Daily inspect the function and existence of the safety 
appliances before you start the unit. 
Do not attempt operation in this case, protect the dust 
collector by unplugging the power cord. 
Always wear the approved working outfit: 
‐ safety goggles 
‐ ear protection 
‐ dust protection 
During the changing or cleaning of the filters it's necessary to 
use a mask (mask with filtration). 
Always disconnect the dust collector from the power source 
(unplug) before servicing or changing filters. 
Wait until the impeller has stopped completely. 
 
Never reach into the machine while it is operating or running 
down. 
 
To reduce the risk of injury from moving parts, always keep 
inlet port covered with the guard provided. 
Hoses or ductwork must be connected before switching on 
the dust‐collector. 
Filter and collection bag must be installed and in proper 
condition, before switching on the dust‐collector 
Make sure that the power cord does not impede work and 
cause people to trip. 
Do not operate the machine under the influence of drugs, 
alcohol or any medication. Be aware that medication can 
change your behaviour. ´ 
 
 
 
Keep children and visitors a safe distance from the work area. 
Never leave a running machine unattended. Before you leave 
the workplace switch off the unit. 
Do not operate the electric tool near inflammable liquids or 
gases. 
Observe the fire fighting and fire alert options, for example 
the fire extinguisher operation and place. 
Do not use the dust collector in a dump environment and do 
not expose it to rain. 
Do not use this equipment to filter volatile fumes or smoke. 
Wood dust is explosive and can also represent a risk to health. 
Dust form some tropical woods in particular, and from 
hardwoods like beach and oak, is classified as a carcinogenic 
substance. 
Do not stand on the machine. 
Connection and repair work on the electrical installation may 
be carried out by a qualified electrician only. 
  
Replace a damaged filter immediately. 
Replace a damaged collection bag immediately. 
Have a damaged or worn power cord replaced immediately. 
3.3 Remaining hazards 
When using the machine according to regulations some 
remaining hazards may still exist. 
Dust can cause injuries. 
The use of incorrect mains supply or a damaged power cord 
can lead to injuries caused by electricity. 
Danger of explosion if not properly grounded. 
 
4.  Machine Specifications 
4.1 Technical data 
Dust inlet 
Air flow Ø125 
Vacuum pressure 
Collector bag capacity 
Collector bag diameter 
Mains 
Input power 
Reference current 
Extension cord (H07RN‐F) 
Installation fuse protection 
Protection class  
Ø125mm (2xØ100mm) 
1200 m³/h 
1880 Pa 
150 L 
500 mm 
1~230V, PE, 50Hz 
1,5kW (2HP) S1 
7.3 A 
3x1,5 mm² 
16A 