Cleaning after each operation
Clean the pump by flushing a appropriate cleaning agent.
l The pump should not be immersed into the
cleaning agent higher than the outlet connection.
l Pump and hose must be compatible with the
cleaning agent.
l Do not use flammable liquids to clean the pump or motor.
l Do not separate the motor from the pump as long as
there is still any backpressure within the system.
First drain pump and discharge hose.
Dismantling of Pumps for Cleaning
l Unplug the pump or disconnect the air supply hose.
1
l Unscrew the union nut between pump and motor.
2
l Remove motor from the pump.
3
l Never store the motor in areas in which corrosive
4
vapours exist.
5
l Dismantling of pump as follows :
5.1
F 424 S-43/38, F 424 S-43/37 Z,
F 424 S-50/45 Z, F 424 PP-41/36,
F 424 PVDF-41/36, F 424 PP-41/35 Z
F 424 PVDF-41/35 Z, F 424 PP-50/43 Z
l Unscrew foot piece.
l Lock coupling on the motorside of the pump by a
wrench or a big screwdriver and unscrew the impellor.
l Take the inner tube out of the pump assembly.