Maintenance and repairs
54
a
b
c
Changing the filter unit
We recommend replacing the filter unit with fluff filter
every six months.
Information
If the cartridge filter or fluff filter is defective, the filter
unit (without the cover) must be replaced.
54
Fig.
Take the filter unit with dust container out of the ro-
bot vacuum. Fig.
Take the dust container out of the filter unit.
43
Fig.
Take the cover off the filter unit.
a) Pull the tab and remove the cover from the filter unit.
b) Dispose of the old filter unit.
Information
The tab on the cover needs to be pulled hard.
c) Fit the cover on the new filter unit – you should hear
it click into place.
Check that the cover is fitted on the filter unit cor-
rectly. The cover must lie flush with the filter unit.
Insert the filter unit with dust container. Fig.
42
en
45