Chapter 1,
General Description
•
The Altair QuickCheck Station is designed to
test the Altair and Altair Pro Single Gas
Detectors, verifying:
•
instrument response to gas (bump check)
•
alarm functionality.
•
The Test Station:
•
uses a microphone
to detect the audible alarm
•
electronically checks the instrument's
visual LED alarm and
standard vibrating alarm
•
tests the instrument's response to a
known concentration of gas
•
is compatible with:
•
all three Altair Detector versions:
•
CO, H 2 S and O 2
•
Altair Pro Detector versions:
•
O 2 , CO, CO Steel, CO Fire,
H 2 S, HCN, Cl 2 ,
ClO 2 , SO 2 , NO 2 and NH 3
•
has three LED indicators:
•
Alarm Test LED
•
Gas Test LED
•
Pass/Fail and Confidence Pulse LED
(indicates unit is receiving power).
NOTE: The Altair and Altair Pro instruments
record the date, time, and result of a bump
test internally in their event recorder:
•
25 events are stored in the
Altair Detector
•
50 events are stored in the
Altair Pro Detector.
1
4
5 6
7
ITEM
NUMBER DESCRIPTION
1
REGULATOR (sold separately - manual version)
2
GAS CYLINDER (sold separately)
3
ALTAIR INSTRUMENT (sold separately)
4
TEST STATION HOUSING
5
ALARM TEST LED
6
GAS TEST LED
7
PASS/FAIL LED
Figure 1-1. Altair QuickCheck Station
Components
2
3
1-1