Focal FDS 4.350 Manuel D'utilisation page 28

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FDS AMPLIFIERS
U s e r m a n u a l
28
3.6 – Wiring power supply to your FDS amplifier
CAUTION
The cable connecting the positive (+) terminal of the battery to the "+ BATT" terminal of the amplifier
MUST be fused (ampere rating: 30 amperes) less than 40cm away from the battery of the vehicle.
The connections on the fuse holder must be fully insulated.
Open the fuse holder, removing the fuse with care. Fix the base of the fuse holder.
Cut a length of power cable between 10 and 40cm (maximum). Strip 1cm, then tin. Screw the cable to
the terminal of the fuse holder (battery side). Crimp the power cable to the intended spade terminal
and screw to battery terminal.
Strip 1cm from the remaining length of cable, then tin. Screw the cable to the other fuse holder terminal.
40cm max
fig. 5
Prepare the positive power cable (+) to connect it to the amplifier by using the adequate Y-type spade
terminal, then block the cable by screwing tight. (fig. 5)