TECHNICAL DATA BATTERY CHARGER
Voltage range ..........................................................................................
Quick charge current ...............................................................................
Maintaining charge current ......................................................................
Battery charging time with 1.5 Ah ............................................................
Battery charging time with 3.0 Ah ............................................................
Weight according EPTA-Procedure 01/2003 ...........................................
Recommended ambient charging temperature .......................................
WARNING! Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in electric
shock, fi re and/or serious injury.
Save all warnings and instructions for future reference.

SAFETY INSTRUCTIONS

Do not dispose of used battery packs in the household refuse or by
burning them. Milwaukee Distributors off er to retrieve old batteries
to protect our environment.
Only the following battery packs can be charged with this charger:
Battery Cat.
Cell
DC Volts
No.
Type
M12B
Li-Ion
M12B2
Li-Ion
M12B3
Li-Ion
M12BX
Li-Ion
M12B4
Li-Ion
M12B6
Li-Ion
M14B
Li-Ion
M14BX
Li-Ion
M14B4
Li-Ion
M18B
Li-Ion
M18B2
Li-Ion
M18BX
Li-Ion
M18B4
Li-Ion
M18B5
Li-Ion
M18B6
Li-Ion
M18B9
Li-Ion
M18HB12
Li-Ion
Do not try to charge non-rechargeable batteries with this charger.
Do not store the battery pack together with metal objects (short
circuit risk).
No metal parts must be allowed to enter the battery section of the
charger (short circuit risk).
Never break open battery packs or chargers and store only in dry
rooms. Keep dry at all times.
The battery clamps of the charger are fed by the mains supply. Do
not touch the tool with conducting objects.
Never charge a damaged battery pack. Replace by a new one.
Before use check machine, cable, and plug for any damages or
material fatigue. Repairs should only be carried out by authorised
Service Agents.
This appliance is not intended to be
used or cleaned by persons with
reduced physical, sensory or mental
capabilities, or lack of experience or
knowledge, unless they have been
given instructions concerning the safe
use of the appliance by a person
legally responsible for their safety.
They should be supervised whilst
using the appliance. Children shall not
8
ENGLISH
414 233 - M12-18C.indd Abs1:8
414 233 - M12-18C.indd Abs1:8
Capacity
Cell No.
12
≤ 1.5 Ah
3
12
≤ 2.0 Ah
3
12
≤ 3.0 Ah
3
12
≤ 3.0 Ah
2 x 3
12
≤ 4.0 Ah
2 x 3
12
≤ 6.0 Ah
2 x 3
14.4
≤ 1.5 Ah
4
14.4
≤ 3.0 Ah
2 x 4
14.4
≤ 4.0 Ah
2 x 4
18
≤ 1.5 Ah
5
18
≤ 2.0 Ah
5
18
≤ 3.0 Ah
2 x 5
18
≤ 4.0 Ah
2 x 5
18
≤ 5.0 Ah
2 x 5
18
≤ 6.0 Ah
2 x 5
18
≤ 9.0 Ah
3 x 5
18
≤ 12.0 Ah
3 x 5
M12-18C
.....12 V, 14,4 V, 18 V
............................3 A
........................500 mA
..........................30 min
..........................60 min
........................704 g
..................... +5...+40 °C
use, clean or play with this appliance,
which when not in use should be
secured out of their reach.
Warning! To reduce the risk of fi re, personal injury, and product
damage due to a short circuit, never immerse your tool, battery
pack or charger in fl uid or al-low a fl uid to fl ow inside them.
Corrosive or conductive fl uids, such as seawater, certain industrial
chemicals, and bleach or bleach containing products, etc., Can
cause a short circuit.
SPECIFIED CONDITIONS OF USE
This charger charges 12V, 14.4V and 18V Milwaukee Li-Ion battery
packs.
Do not use this product in any other way as stated for normal use.

MAINS CONNECTION

Connect only to single-phase AC current and only to the system
voltage indicated on the rating plate. It is also possible to connect
to sockets without an earthing contact as the design conforms to
safety class II.

CHARGING TIME

Battery Cat. No.
Volts
M12B
12 V
M12B2
12 V
M12B3
12 V
M12BX
12 V
M12B4
12 V
M12B6
12 V
M14B
14,4 V
M14BX
14,4 V
M14B4
14,4 V
M18B
18 V
M18B2
18 V
M18BX
18 V
M18B4
18 V
M18B5
18 V
M18B6
18 V
M18B9
18 V
M18HB12
18 V
LI-ION BATTERIES
The rechargeable batteries are partially charged. The LED on the
battery indicates the state of charge.
If it is not used for long periods, the rechargeable battery will
switch to the non-operative state.
When fully discharged the rechargeable battery switches off
automatically (depth discharge not possible).
Under extreme circumstances, the internal temperature of the
battery could become too high. If this happens, the battery will shut
down.
Place the battery on the charger to charge and reset it.
The state of charge can be read by pressing the button on the
rechargeable battery. The battery can be left in the electric tool
while the reading is taken but it must be switched off at least one
minute beforehand (otherwise the display will be inaccurate). The
number of LEDs illuminated indicates the state of charge. A
fl ashing LED indicates a max. power reserve of 10%.
Capacity
Charging Time
max.
≤ 1.5 Ah
40 min
≤ 2.0 Ah
40 min
≤ 3.0 Ah
72 min
≤ 3.0 Ah
75 min
≤ 4.0 Ah
75 min
≤ 6.0 Ah
133 min
≤ 1.5 Ah
40 min
≤ 3.0 Ah
75 min
≤ 4.0 Ah
75 min
≤ 1.5 Ah
40 min
≤ 2.0 Ah
40 min
≤ 3.0 Ah
75 min
≤ 4.0 Ah
75 min
≤ 5.0 Ah
75 min
≤ 6.0 Ah
131 min
≤ 9.0 Ah
191 min
≤ 12.0 Ah
250 min