Technical Data; Safety Instructions; Mains Connection - Milwaukee M12-18 FC Notice Originale

Masquer les pouces Voir aussi pour M12-18 FC:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12

TECHNICAL DATA

Voltage range ...................................................................................
Quick charge current ........................................................................
Battery charging time with 12 V / 1.5 Ah...........................................
Battery charging time with 18 V / 5.0 Ah...........................................
Battery charging time with 18 V / 6.0 Ah...........................................
Battery charging time with 18 V / 9.0 Ah...........................................
Weight according EPTA-Procedure 01/2003 ....................................
WARNING! Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in electric
shock, fi re and/or serious injury.
Save all warnings and instructions for future reference.

SAFETY INSTRUCTIONS

Do not dispose of used battery packs in the household refuse or by
burning them. Milwaukee Distributors offer to retrieve old batteries
to protect our environment.
Only the following battery packs can be charged with this charger:
Battery Cat. No.
DC Volts
M12B
12
M12BX
12
M12B2
12
M12B3
12
M12B4
12
M12B6
12
M14B
14
M14BX
14
M14B4
14
M18B
18
M18BX
18
M18B2
18
M18B4
18
M18B5
18
M18B6
18
M18B9
18
Do not try to charge non-rechargeable batteries with this charger.
Do not store the battery pack together with metal objects (short
circuit risk).
No metal parts must be allowed to enter the battery section of the
charger (short circuit risk).
Never break open battery packs or chargers and store only in dry
rooms. Keep dry at all times.
The battery clamps of the charger are fed by the mains supply. Do
not touch the tool with conducting objects.
Never charge a damaged battery pack. Replace by a new one.
Before use check machine, cable, and plug for any damages or
material fatigue. Repairs should only be carried out by authorised
Service Agents.
This appliance is not intended to be
used or cleaned by persons with
reduced physical, sensory or mental
capabilities, or lack of experience or
knowledge, unless they have been
given instructions concerning the safe
use of the appliance by a person
legally responsible for their safety.
8
ENGLISH
414 697 - M12-18FC.indd Abs1:8
414 697 - M12-18FC.indd Abs1:8
BATTERY CHARGER
.....12 V, 14,4 V, 18 V
............................6 A
..........................20 min
..........................59 min
..........................90 min
..........................90 min
........................703 g
Capacity
Cell No.
≤ 1.5 Ah
3
≤ 3.0 Ah
2 x 3
≤ 2.0 Ah
3
≤ 3.0 Ah
3
≤ 4.0 Ah
2 x 3
≤ 6.0 Ah
2 x 3
≤ 1.5 Ah
4
≤ 3.0 Ah
2 x 4
≤ 4.0 Ah
2 x 4
≤ 1.5 Ah
5
≤ 3.0 Ah
2 x 5
≤ 2.0 Ah
5
≤ 4.0 Ah
2 x 5
≤ 5.0 Ah
2 x 5
≤ 6.0 Ah
2 x 5
≤ 9.0 Ah
3 x 5
M12-18 FC
They should be supervised whilst
using the appliance. Children shall not
use, clean or play with this appliance,
which when not in use should be
secured out of their reach.
SPECIFIED CONDITIONS OF USE
This charger charges 12V, 14.4V and18V Milwaukee Li-Ion battery
packs.
Do not use this product in any other way as stated for normal use.

MAINS CONNECTION

Connect only to single-phase AC current and only to the system
voltage indicated on the rating plate. It is also possible to connect
to sockets without an earthing contact as the design conforms to
safety class II.
LI-ION BATTERIES
The rechargeable batteries are partially charged. The LED on the
battery indicates the state of charge.
If it is not used for long periods, the rechargeable battery will
switch to the non-operative state.
When fully discharged the rechargeable battery switches off
automatically (depth discharge not possible).
Under extreme circumstances, the internal temperature of the
battery could become to high. If this happens, the battery will shut
down.
Place the battery on the charger to charge and reset it.
The state of charge can be read by pressing the button on the
rechargeable battery. The battery can be left in the electric tool
while the reading is taken but it must be switched off at least one
minute beforehand (otherwise the display will be inaccurate). The
number of LEDs illuminated indicates the state of charge. A
fl ashing LED indicates a max. power reserve of 10%.
As a general principle, if the electric tool should fail to work after
inserting the rechargeable battery, then the battery should be
plugged into the charger. The displays on the battery and charger
will then provide information about the condition of the battery.
In low temperatures work may continue at reduced output.
CHARACTERISTICS
After inserting the battery into the reception of the charger the
battery will automatically be charged (red control lamp is
illuminated continuously)
When a hot or cold battery pack is inserted into the charger
(fl ashing red lamp), charging will begin automatically once the
battery reaches the correct charging temperature (0°C...65°C). The
max. charging current is fl owing when the temperature of the
Li-Ion-battery is between 0°C and 65°C.
The battery's charging time is between 1 min and 20 min (at
1,5 Ah), depending on the state of discharge.
Once the battery is fully charged, the LED on the charger changes
from red to green.
Remove the battery pack from the tool for charging when
convenient for you and your job. Milwaukee batteries do not
develop a "memory" when charged after only a partial discharge. It
15.06.2016 22:05:36
15.06.2016 22:05:36

Publicité

Table des Matières
loading

Table des Matières