Evaporative Wick
9. When placing the wick back into the humidifier, the
rod and float assembly must also be reattached.
Insert the top of the float rod through the hole on
the extended wick retainer (attached to the top of
the wick frame). (A). Holding the float in place,
lower the wick and float assembly together into the
cabinet. The wick has a mounting rib on the top
edge which hooks over a rib at the inside back of
the cabinet. NOTE: The float rod retainer must be
extended prior to inserting the float rod. The white
float must be positioned into the pocket in the bot-
tom of the cabinet. (B).
B
EN
Air Cleaning Filter (optional)
10. The AirCare filter has four tangs that engage into
four keyhole slots that mount the AirCare filter onto
the outside of the back of the cabinet. (C).
Chassis/Power Pack
11. Place the chassis/power pack unit into the cabinet,
so it fits without tipping or rocking.
12. Fill the bottle water. If you only have softened
water available in your home, you can use it, but
you will notice a build-up of minerals on the wick
much sooner. The bottle holds 2.5 gallons. When
filling, be careful not to pressurize it by overfilling.
Bottle damage can result from this. A fill hose is
provided with your humidifier which will fit most
faucets. Place the water bottle into the left side of
the humidifier with the valve cap end down, so that
the groove in the water bottle faces the inside. (D).
Replace the water bottle cover.