Pos.
Description
1
Maintenance cover
2
Flange screws
To gain access to the safety valve (Pos. 3), please proceed as follows:
1. Remove the raw air pipe installed by the customer.
2. Remove the flange screws (Pos. 2) on the maintenance cover.
3. Open the maintenance cover (Pos. 1).
4. Loosen the knurled screw (Pos. 4) on the compressed air safety valve
(Pos. 3) by turning it anti-clockwise and open it by approx. 3 – 4 turns
until the exhaust air process starts. (audible discharge of compressed
air)
5. Allow the compressed air safety valve to blow off briefly.
6. Screw in the knurled screw (Pos. 4) as far as it will go and hand-tighten
it.
7. Close the maintenance cover (Pos. 1) and reconnect the raw air pipe to
the product.
8. Put the product back into operation. See chapter "Commissioning"
1502029-00
Fig. 25: Access to the compressed air safety valve
Tab. 28: Positions on the product
Pos.
Description
3
Compressed air safety valve
4
Knurled screw
- 79 -