NOTE
Products with W3 certification according to requirements for W3/IFA
certified welding fume separation class. (See "Technical data" chapter)
The W3 approval becomes void if:
•
The product is used other than as intended or is subject to
constructive modifications.
•
Non-original spare parts, in accordance with the spare parts list, are
used.
•
Only original replacement filters, because they guarantee the necessary
filter efficiency and are matched to the product and its performance
characteristics.
•
Switch the product off using the on/off switch.
•
Secure the product against unintentional switching on. If available, pull
out the mains plug or secure the main switch in the 0 position with a
padlock.
•
Disconnect the pressure supply, if present, and let the compressed air
present in the product flow out via the condensate drain valve.
7.2.4 Changing filters
Perform the filter change as follows:
1. Switch off the product and disconnect it from the power supply by
unplugging.
2. Disconnect the product from the compressed air network and allow any
stored compressed air to escape from the system.
3. Make sure the original replacement filter cartridges and the enclosed
disposal bag are available.
1502029-00
- 75 -
EN