Venting Requirements
WARNING
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death or
fire.
WARNING:
To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances. Dryer
exhaust must not be connected into any gas vent, chimney, wall,
ceiling, attic, crawlspace, or a concealed space of a building. Only
rigid or flexible metal vent shall be used for exhausting.
� Only a 4" (102 mm) heavy metal exhaust vent and clamps may
be used.
� Do not use plastic or metal foil vent.
Rigid metal vent:
� Recommended for best drying performance and to avoid
crushing and kinking.
Flexible metal vent (acceptable only if accessible to clean):
� Must be fully extended and supported in final dryer location.
� Remove excess to avoid sagging and kinking that may result
in reduced airflow and poor performance.
� Do not install in enclosed walls, ceilings, or floors.
� The total length should not exceed 7
� The length of flexible metal vent used must be included in the
overall vent system design as shown in the "Vent System
Chart."
Home Venting System:
� If using an existing home vent system, clean lint from the entire
length of the system before installing the dryer.
� Make sure external exhaust hoods outside of the home is not
plugged with lint or other outside debris.
� Replace plastic of metal foil vents with rigid metal or flexible
metal vents. Review "Vent System Chart" and, if necessary,
modify existing home vent system to achieve best drying
performance.
Exhaust hoods:
� An exhaust hood should cap the vent to keep rodents and
insects from entering the home.
� Must be at least 12" (305 mm) from ground or any object that
may obstruct exhaust (such as flowers, rocks, bushes, or
snow).
� Do not use an exhaust hood with a magnetic latch.
Fire Hazard
3
/
ft (2.4 m).
4
Recommended Styles:
Louvered Hood
Elbows:
� 45° elbows provide better airflow than 90° elbows.
Clamps:
� Use clamps to seal all joints.
� Exhaust vent must not be connected or secured with screws or
other fastening devices that extend into interior of duct and
catch lint. Do not use duct tape.
Vent products can be purchased from your dealer. For contact and
ordering information, refer to your Quick Start Guide.
Plan Vent System
Recommended exhaust installations:
Typical installations vent the dryer from the rear of the dryer. Other
installations are possible.
A. Dryer
B. Elbow
C. Wall
D. Exhaust hood
E. Clamps
Acceptable Style:
Box Hood
Angled Hood
F. Rigid metal or flexible metal vent
G. Vent length necessary to connect
elbows
H. Exhaust outlet
I.
Optional side exhaust outlet
13