Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

DRYER INSTALLATION INSTRUCTIONS
INSTRUCTIONS POUR L'INSTALLATION
Table of Contents
DRYER SAFETY ......................................................................... 2
INSTALLATION REQUIREMENTS ............................................. 4
Tools and Parts ...................................................................... 4
LOCATION REQUIREMENTS .................................................... 5
ELECTRICAL REQUIREMENTS - U.S.A. ONLY ....................... 7
GAS DRYER POWER HOOKUP ................................................ 8
INSTALL LEVELING LEGS ....................................................... 10
Power Supply Cord Connection ......................................... 12
Direct Wire Connection ....................................................... 14
MAKE GAS CONNECTION ...................................................... 17
VENTING ................................................................................... 18
Venting Requirements ......................................................... 18
Plan Vent System ................................................................. 19
Install Vent System .............................................................. 20
CONNECT VENT ...................................................................... 22
LEVEL DRYER .......................................................................... 23
COMPLETE INSTALLATION CHECKLIST .............................. 23
DOOR REVERSAL (OPTIONAL) .............................................. 24
INSTALLATION NOTES
_________________________________
Date of purchase:
________________________________
Date of installation:
________________________________________
Installer:
___________________________________
Model number:
____________________________________
Serial number:
DE LA SÉCHEUSE
Para una version de estas instrucciones en español, visite www.Whirlpool.com

Table des matières

SÉCURITÉ DE LA SÉCHEUSE ................................................ 30
EXIGENCES D'INSTALLATION ............................................... 32
Outillage et pièces ............................................................... 32
EXIGENCES D'EMPLACEMENT ............................................. 33
CANADA SEULEMENT ............................................................ 36
RACCORDEMENT D'UNE SÉCHEUSE À GAZ ...................... 37
RACCORDEMENT AU GAZ ..................................................... 39
ÉVACUATION ........................................................................... 40
Exigences concernant l'évacuation ................................... 40
Planification du système d'évacuation .............................. 41
Installation du système d'évacuation ................................ 42
(MODÈLE À VAPEUR UNIQUEMENT) .................................... 43
RÉGLAGE DE L'APLOMB DE LA SÉCHEUSE........................ 45
INVERSION DE LA PORTE (FACULTATIF) .............................. 46
NOTES CONCERNANT L'INSTALLATION
_____________________________________
Date d'achat:
________________________________
Date d'installation:
______________________________________
Installateur:
________________________________
Numéro de modéle:
__________________________________
Numéro de série:
W11183136A
W11183139A-SP

Publicité

Table des Matières
loading

Sommaire des Matières pour Whirlpool W11183136A

  • Page 1: Table Des Matières

    ACHEVER L’INSTALLATION LISTE DE VÉRIFICATION ..45 LEVEL DRYER ................23 INVERSION DE LA PORTE (FACULTATIF) ......46 COMPLETE INSTALLATION CHECKLIST ......23 DOOR REVERSAL (OPTIONAL) ..........24 Para una version de estas instrucciones en español, visite www.Whirlpool.com INSTALLATION NOTES NOTES CONCERNANT L’INSTALLATION _________________________________ _____________________________________ Date of purchase: Date d’achat:...
  • Page 2: Dryer Safety

    DRYER SAFETY...
  • Page 3 WARNING: FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage. – Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. –...
  • Page 4: Installation Requirements

    INSTALLATION REQUIREMENTS Tools needed for gas installations: Tools and Parts Gather the required tools and parts before starting installation. Tools needed for all installations: 8" (203 mm) or 10" 8" (203 mm) or 10" (254 mm) pipe wrench (254 mm) adjustable wrench (for gas connections) Flat-blade screwdriver #2 Phillips screwdriver...
  • Page 5: Location Requirements

    Refer to your Use and Care Guide for information about accessories available for your dryer. LOCATION REQUIREMENTS Side view: Check code requirements. Some codes limit, or do not permit, Whirlpool Models installing dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector. " (1378 mm) You will need: A location allowing for proper exhaust installation.
  • Page 6 Recommended installation clearances (dryer only): Back view: " (159 mm) 3" (76 mm) 18" min. "* 48 in. min. (457 mm) (759 mm) Water inlet (310 cm (Steam Models Only) "* Vent "* (146 mm) (89 mm) 0–5" 24 in. min.
  • Page 7: Electrical Requirements - U.s.a. Only

    ELECTRICAL REQUIREMENTS – If your outlet looks like this: U.S.A. ONLY Then choose a 4-wire power supply cord with ring or spade terminals and UL Listed strain relief. The 4-wire power supply cord, at least It is your responsibility: 4 ft. (1.22 m) long, must have four 10-gauge To contact a qualified electrical installer.
  • Page 8: Electric Dryer Power Hookup - Canada Only

    ELECTRIC DRYER POWER HOOKUP – GAS DRYER POWER HOOKUP CANADA ONLY ELECTRICAL REQUIREMENTS ELECTRICAL REQUIREMENTS It is your responsibility: To contact a qualified electrical installer. ■ To be sure that the electrical connection is adequate and in ■ 120 volt, 60 Hz, AC-only, 15 or 20 amp fused electrical ■...
  • Page 9 GAS SUPPLY REQUIREMENTS Option 2 (Alternate Method) Approved aluminum or copper tubing: WARNING Must include 1/8" NPT minimum plugged tapping accessible ■ for test gauge connection, immediately upstream of the gas connection to the dryer. See illustration below. 1/2" IPS pipe is recommended. ■...
  • Page 10: Install Leveling Legs

    INSTALL LEVELING LEGS GAS SUPPLY CONNECTION REQUIREMENTS Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting ■ between the flexible gas connector and the dryer gas pipe, as needed to avoid kinking. Use only pipe-joint compound. Do not use TEFLON tape.
  • Page 11: Make Electrical Connection - U.s.a. Only

    For direct wire installations: MAKE ELECTRICAL CONNECTION – U.S.A. ONLY ELECTRICAL CONNECTION Power Supply Cord: Remove terminal block cover Before you start: disconnect power. Choose electrical connection type Power supply cord 4-wire receptacle (NEMA Type 14-30R). Go to “Power Supply Cord Connection.” Power supply cord 3-wire receptacle (NEMA Type 10-30R).
  • Page 12: Power Supply Cord Connection

    Power Supply Cord Connection 4-Wire Power Supply Cord Connection IMPORTANT: A 4-wire connection is required for mobile homes Power supply cord strain relief and where local codes do not permit the use of 3-wire connections. Attach power supply cord strain relief 4-wire receptacle 4 prong plug (NEMA type 14-30R)
  • Page 13 Remove center screw Connect ground wire Connect ground wire (F) (green or bare) of power supply cord Remove center terminal block screw (B). under green external ground conductor screw (A). Tighten screw. Connect neutral wire Connect remaining wires Connect neutral wire (white or center) (C) of power supply cord under center terminal block screw (B).
  • Page 14: Direct Wire Connection

    Direct Wire Connection 4-Wire Direct Wire Connection IMPORTANT: A 4-wire connection is required for mobile homes Direct wire strain relief and where local codes do not permit 3-wire connections. Prepare your 4-wire cable Attach direct wire strain relief for direct connection Direct wire cable must have 5 ft.
  • Page 15 Connect ground wire Remove center screw Connect ground wire (green or bare) (F) of direct wire cable Remove center terminal block screw (B). under green external ground conductor screw (A). Tighten screw. Connect neutral wire Connect remaining wires Place hooked end of neutral wire (white or center) (C) of direct wire cable under center terminal block screw (B), hook Place hooked ends of remaining direct wire cable wires under...
  • Page 16 Optional External Ground for 3-Wire Connect external ground wire Connection (Power Supply Cord Shown) IMPORTANT: You must verify with a qualified electrician that this grounding method is acceptable before connecting. Prepare to connect neutral ground wire and neutral wire Connect a separate copper ground wire (G) under the green external ground conductor screw (A) to an adequate ground.
  • Page 17: Make Gas Connection

    MAKE GAS CONNECTION Plan pipe fitting connection (Option 1) (Gas models only) WARNING Explosion Hazard Use a new CSA International approved gas supply line. Install a shut-off valve. A. 3/8" flexible gas connector C. 3/8" to 3/8" pipe elbow Securely tighten all gas connections. B.
  • Page 18: Venting

    VENTING Exhaust hoods: An exhaust hood should cap the vent to keep rodents and ■ Venting Requirements insects from entering the home. Must be at least 12" (305 mm) from ground or any object ■ that may obstruct exhaust (such as flowers, rocks, bushes, or snow).
  • Page 19: Plan Vent System

    Plan Vent System Special provisions for mobile homes: Exhaust vent must be securely fastened to a noncombustible portion of mobile home and must not terminate beneath the Recommended exhaust installation: mobile home. Terminate exhaust vent outside. A. Dryer F. Rigid metal or flexible B Elbow metal vent C.
  • Page 20: Install Vent System

    Long Vent System Chart Connect vent to exhaust hood Number of Type Angled 90° elbows of vent hoods Rigid metal 160 ft. (48.8 m) Rigid metal 150 ft. (45.7 m) Rigid metal 140 ft. (42.7 m) Rigid metal 130 ft. (39.6 m) Rigid metal 120 ft.
  • Page 21: Connect Inlet Hose (Steam Model Only)

    CONNECT INLET HOSE Tighten couplings (STEAM MODEL ONLY) For non-steam models, skip to “Connect Vent.” The dryer must be connected to the cold water faucet using the new inlet hoses (not supplied). Do not use old hoses. NOTE: Replace inlet hoses after 5 years of use to reduce the risk of hose failure.
  • Page 22: Connect Vent

    CONNECT VENT Attach long hose to dryer fill valve and tighten coupling Connect vent to exhaust outlet Using a 4" (102 mm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure vent is clean. Dryer vent must fit over dryer exhaust outlet and inside exhaust hood.
  • Page 23: Level Dryer

    LEVEL DRYER COMPLETE INSTALLATION CHECKLIST Level dryer Check that all parts are now installed. If there is an extra part, go back through steps to see what was skipped. Check that you have all of your tools. Dispose of/recycle all packaging materials. Place Be sure the water faucets are on.
  • Page 24: Door Reversal (Optional)

    DOOR REVERSAL (OPTIONAL) ALL DOORS: The following instructions are for models with round and square-shaped doors. Remove door from dryer Tools needed: #2 Phillips screwdriver Min. 8" (203 mm) long TORX ® , T20 ® and T25 ® † screwdrivers REVERSE DOOR SWING: ROUND-SHAPED DOOR DOORS WITH ELECTRICAL WIRING: IMPORTANT: If the protective film has not yet been removed...
  • Page 25 Remove inner door from outer door Remove latch Thin section Latch Thick section Top of Flip and rotate the inner door 180° so that the thin section is door at the top and the thick section is at the bottom. Using a T25 ®...
  • Page 26 Reinstall hinge assembly on opposite side Reposition rotating assembly and tubing Flip over the inner door to the left. Using a T20 screwdriver, ® reinstall the hinge assembly on the opposite side from which Reposition rotating assembly and tubing 180 ° to opposite side it was removed.
  • Page 27 ALL DOORS: DOORS WITH ELECTRICAL WIRING: Reinstall inner door assembly Reconnect wiring Swing down Plug in wire. Using a Phillips screwdriver, secure the rotating Bottom assembly to the hinge with the screw removed earlier. of door Position the door with the inside of the door facing up. Using a Phillips screwdriver, reinstall the 10 screws removed earlier, securing the inner door to the outer door.
  • Page 28 REVERSE DOOR SWING: SQUARE-SHAPED DOOR Remove inner door from outer door Remove door from dryer Release tab Release tab Position the door with the inside of the door facing up. Using a T25 screwdriver, remove the four screws securing ® Using a Phillips screwdriver, remove the 13 screws securing the door hinge to the dryer and lift up and out to remove the inner door to the outer door.
  • Page 29 Reinstall hinge and latch Reattach door to dryer on opposite sides Latch Hinge Using a T25 screwdriver, reinstall the latch plate and ® Using a T25 screwdriver, reinstall the four screws securing ® hinge assembly on the opposite sides from which they the door hinge to the dryer.
  • Page 30: Sécurité De La Sécheuse

    SÉCURITÉ DE LA SÉCHEUSE...
  • Page 31 AVERTISSEMENT : RISQUE D ’ INCENDIE OU D ’ EXPLOSION Le non-respect des avertissements de sécurité peut causer des dommages à la propriété, des blessures graves, voire la mort. – Ne pas entreposer ou utiliser de l’essence ou d’autres vapeurs ou liquides inflammables à...
  • Page 32: Exigences D'installation

    EXIGENCES D’INSTALLATION Outils nécessaires aux installations au gaz : Outillage et pièces Rassembler les outils et composants nécessaires avant d’entreprendre l’installation. Outils nécessaires pour toutes les installations : Clé à tuyau de 8" (203 mm) Clé à mollette de 8" ou 10"...
  • Page 33: Exigences D'emplacement

    Des pièces supplémentaires seront peut-être nécessaires, selon Un plancher de niveau ayant une pente maximale ■ l’installation. Consulter les codes locaux. Vérifier l’alimentation de 1" (25 mm) sous l’ensemble de la sécheuse. Si la pente est supérieure à 1" (25 mm), installer un ensemble électrique et le circuit d’évacuation existants.
  • Page 34 *Mesures approximatives (654 mm) Vue latérale : REMARQUE : La plupart des installations requièrent un espace minimum de 5" (127 mm) derrière la sécheuse pour le Modèles de Whirlpool conduit d’évacuation avec coude. Voir “Exigences concernant l’évacuation.” " (1378 mm) *Mesures approximatives Modèles de Maytag...
  • Page 35 Distances de dégagement à respecter Installation sous comptoir personnalisée : Pour chaque aménagement, prévoir davantage d’espace pour faciliter l’installation et l’entretien, des espacements pour les appareils voisins, les murs, les portes et les plinthes. L’espace doit être assez grand pour permettre l’ouverture complète de la porte.
  • Page 36: Sécheuse Électrique Raccordementà L'alimentation Électrique - Canada Seulement

    SÉCHEUSE ÉLECTRIQUE INSTRUCTIONS DE LIAISON À LA TERRE RACCORDEMENT À L’ALIMENTATION Pour une sécheuse reliée à la terre et connectée par ÉLECTRIQUE – CANADA SEULEMENT un cordon : Cette sécheuse doit être reliée à la terre. En cas de mauvais SPÉCIFICATIONS ÉLECTRIQUES fonctionnement ou de panne, la liaison à...
  • Page 37: Raccordement D'une Sécheuse À Gaz

    Cette sécheuse doit être équipée du brûleur convenable, ■ INSTRUCTIONS DE LIAISON À LA TERRE correspondant au gaz spécifique qui alimente l’habitation. L’information sur le brûleur se trouve sur la plaque Pour une sécheuse reliée à la terre et connectée par signalétique dans le logement de la porte de la sécheuse.
  • Page 38: Installation Des Pieds De Nivellement

    INSTALLATION DES PIEDS Au Canada : Un robinet d’arrêt individuel manuel doit être installé DE NIVELLEMENT conformément à la norme B149.1 du Code des installations au gaz naturel ou propane. On recommande qu’un robinet d’arrét manuel individuel soit installé à moins de 6 pi (1,8 m) de la sécheuse.
  • Page 39: Raccordement Au Gaz

    RACCORDEMENT AU GAZ Planifier le raccordement du raccord (modèles de sécheuses à gaz uniquement) (option 1) AVERTISSEMENT Risque d’explosion Utiliser une canalisation neuve d’arrivée de gaz approuvée par CSA International. Installer un robinet d’arrêt. A. Raccord de gaz flexible C. Coude de canalisation Bien serrer chaque organe de connexion de la de 3/8"...
  • Page 40: Évacuation

    ÉVACUATION Conduit métallique rigide Recommandé pour une meilleure performance de séchage ■ Exigences concernant l’évacuation et pour réduire les risques d’écrasement et de déformation. Conduit métallique flexible (Acceptable uniquement si accessible pour le nettoyage) Doit être complètement déployé et supporté dans ■...
  • Page 41: Planification Du Système D'évacuation

    Coudes : Les coudes à 45° permettent une meilleure circulation de l’air ■ que les coudes à 90°. Meilleur Brides de serrage : Utiliser des brides de serrages pour sceller tous les joints. ■ Le conduit d’évacuation ne doit pas être connecté ou fixé avec ■...
  • Page 42: Installation Du Système D'évacuation

    Installation du système d’évacuation Déterminer l’itinéraire d’acheminement du conduit : Choisir l’itinéraire d’acheminement vers l’extérieur qui sera ■ le plus direct et le plus rectiligne. Installer le clapet d’évacuation Planifier l’installation pour introduire le nombre minimal ■ de coudes et de changements de direction. Si des coudes ou changements de direction sont utilisés, ■...
  • Page 43: Raccordement Du Tuyau D'alimentation (Modèle À Vapeur Uniquement)

    RACCORDEMENT DU TUYAU Serrer les raccords D’ALIMENTATION (MODÈLE À VAPEUR UNIQUEMENT) Pour les modèles sans vapeur, passer directement à la section “Raccordement du conduit d’évacuation.” La sécheuse doit être connectée au robinet d’eau froide à l’aide des nouveaux tuyaux d’alimentation (non fournis). Ne pas utiliser de tuyaux usagés.
  • Page 44: Raccordement Du Conduit D'évacuation

    RACCORDEMENT DU CONDUIT Fixer le long tuyau à l’électrovanne D’ÉVACUATION de remplissage de la sécheuse et serrer les raccords Raccorder le conduit d’évacuation à la bouche d’évacuation À l’aide d’une bride de serrage de 4" (102 mm), relier le conduit d’évacuation à la bouche d’évacuation de la sécheuse.
  • Page 45: Réglage De L'aplomb De La Sécheuse

    RÉGLAGE DE L’APLOMB ACHEVER L’INSTALLATION DE LA SÉCHEUSE LISTE DE VÉRIFICATION Vérifier que toutes les pièces sont maintenant installées. S’il reste une pièce, passer en revue les différentes étapes Régler l’aplomb de la sécheuse pour découvrir laquelle aurait été oubliée. Vérifier la présence de tous les outils.
  • Page 46: Inversion De La Porte (Facultatif)

    INVERSION DE LA PORTE TOUTES LES PORTES : (FACULTATIF) Retirer la porte de la sécheuse Les instructions suivantes correspondent aux modèles avec porte ronde et carrée. Outils nécessaires : Tournevis Phillips n° 2 Tournevis TORX ® , T20 ® de 8" (203 mm) min. ®...
  • Page 47 Enlever le loquet Dégager la porte interne de la porte externe Section mince Loquet Section épaisse Inverser et faire pivoter l’intérieur de porte de 180° pour que Haut de la section mince se situe en haut et la section épaisse en bas. la porte À...
  • Page 48 Réinstaller la charnière sur l’autre côté Replacer l’ensemble de rotation et le tube Inverser l’intérieur de porte vers la gauche. À l’aide d’un tournevis T20 , réinstaller la charnière sur le côté opposé ® Replacer l’ensemble de rotation et le tube de 180°, du côté (par rapport à...
  • Page 49 TOUTES LES PORTES : PORTES AVEC CÂBLAGE ÉLECTRIQUE : Réinstaller l’intérieur de porte Reconnecter le câblage Ouvrir vers le bas Brancher le câblage. À l’aide d’un tournevis cruciforme, fixer Bas de la porte l’ensemble de rotation à la charnière en utilisant la vis enlevée précédemment.
  • Page 50 INVERSION DU SENS D’OUVERTURE DE LA PORTE CARRÉE Dégager la porte interne de la porte externe Retirer la porte de la sécheuse Patte de dégagement Patte de dégagement Positionner la porte de façon à ce que l’intérieur de la porte soit orienté...
  • Page 51 Réinstaller la charnière et le loquet Réinstaller la porte sur la sécheuse sur chaque côté Loquet Charnière À l’aide d’un tournevis T25 , réinstaller la plaque de protection ® du loquet, la plaque de support du loquet et la charnière sur À...
  • Page 52 W11183136A ©2018 All rights reserved. Used under license in Canada. W11183139A-SP Tous droits réservés. Utilisé sous licence au Canada. 04/18...

Ce manuel est également adapté pour:

W11183139a-sp

Table des Matières