Valor Legend G3.5 Serie Instructions D'installation

Masquer les pouces Voir aussi pour Legend G3.5 Serie:

Publicité

Liens rapides

This appliance is certifi ed for use from 0–4500 feet. For
altitudes above 4500 feet, see local codes.
Kit Contents
1 Pilot injector
1 Burner
1 Main burner elbow injector
1 Set of conversion labels
1 Set of air shutter
1 By-pass screw
Tools Required
• Wrenches, to disconnect gas line
• Phillips (+) screwdriver, to remove burner module
• Small (jewelers size) fl at blade screwdriver, to set
pressure
• Small fl at blade screwdriver, to release pressure tap
on valve
• Nut driver 8 mm or 5/16", to remove burner nuts
• Needle nose pliers, to remove by-pass screw
• Hex (Allen) wrench, 4 mm or 5/32", to remove pilot
injector
• Manometer, to set pressure
Specifi cations
Model
Gas
Altitude (Ft.)*
Input Maximum (Btu/h)
Input Minimum (Btu/h)
Manifold Pressure (in w.c.)
Minimum Supply Pressure
(in w.c.)
Maximum Supply Pressure
(in w.c.)
Main Burner Injector Marking
Pilot Injector Marking
Min. Rate By-Pass Screw
4006429-02
©2017, Miles Industries Ltd.
Legend G3.5
Gas Conversion Kit
700JNGK & 700JPGK
Use with with Valor Models 700J Heaters ONLY
Installation Instructions
700JN
700JP
Natural
Propane
0-4,500 feet*
26,000
26,000
10,000
10,000
3.5
10.0
5.0
11.0
10.0
14.0
750
260
51
30
150
105
WARNING
This conversion kit shall be installed by a
qualifi ed service agency in accordance with
the manufacturer's instructions and all appli-
cable codes and requirements of the authority
having jurisdiction. If the information in these
instructions is not followed exactly, a fi re, ex-
plosion or production of carbon monoxide may
result causing property damage, personal in-
jury or loss of life. The qualifi ed service agency
is responsible for the proper installation of this
kit. The installation is not proper and complete
until the operation of the converted appliance
is checked as specifi ed in the manufacturer's
instructions supplied with the kit.
Use this manual in conjunction with the instal-
lation manual supplied with the appliance.
Natural Gas Burner:
Has two interlaced rows of slots
Propane Gas Burner: marked "LPG"
Has single row of slots and two rows
of small holes
Burner identifi cation

Publicité

loading

Sommaire des Matières pour Valor Legend G3.5 Serie

  • Page 1 Legend G3.5 Gas Conversion Kit 700JNGK & 700JPGK Use with with Valor Models 700J Heaters ONLY Installation Instructions This appliance is certifi ed for use from 0–4500 feet. For WARNING altitudes above 4500 feet, see local codes. This conversion kit shall be installed by a Kit Contents qualifi...
  • Page 2 General Notes Regarding Conversion 2. Remove the 2 screws securing the burner brackets to the burner tray. The conversion may be done before or after the appliance is installed into the cavity. However, the gas Burner—top view must be connected to set the manifold pressure. Shut-off...
  • Page 3 Increases pressure 3. Reinstall the right side access door. Decreases pressure Designed and Manufactured by / for Miles Industries Ltd. 190–2255 Dollarton Highway, North Vancouver, BC, CANADA V7H 3B1 Tel. 604-984-3496 Fax 604-984-0246 www.valorfi replaces.com © Copyright Miles Industries Ltd., 2017...
  • Page 4 LE PREMIER FOYER À GAZ RADIANT Kit de conversion de gaz 700JNGK et 700JPGK Pour utilisation avec les foyers Valor 700J SEULEMENT Directives d’installation Cet appareil est homologué pour utilisation de 0 à 4 AVERTISSEMENT 500 pieds. Pour altitudes au-dessus de 4 500 pieds, Ce kit de conversion doit être installé...
  • Page 5 À propos de la conversion 2. Enlevez les 2 vis retenant les supports du brûleur à la plaque. La conversion d’un gaz à l’autre peut être faite avant Dessus du ou après l’installation de l’appareil dans la cavité. brûleur Cependant, le gaz doit être branché pour régler la pression d’admission.Coupez l’alimentation de gaz avant de commencer la conversion.
  • Page 6 Réglez et vérifi ez la pression d’admission et 5. Vérifi ez l’aération et ajustez l’obturateur d’air si nécessaire. l’aération 4 mm 6 mm Écran de retour Réglez la pression d’admission. Espace AERATION GAP de fl ammes d’aération 1. Enlevez le panneau d’accès à la soupape (5 vis) à gauche de l’appareil.

Ce manuel est également adapté pour:

Legend g3.5 700jngkLegend g3.5 700jpgk