POWER SUPPLY
FLASHLIGHT FUNCTION
PROTECTIONS
This device is protected against short-circuits, overloads, deeply discharge and polarity inversions.
ANOMALIES, CAUSES, REMÈDES
TROUBLESHOOTING
No response while pres-
1
sing the ON/OFF button
«Error» light ON on the
2
jumper cable.
«Error» light flashes red +
3
alarm beep.
The «Start» and «Error»
4
indicators stay on.
10
All manuals and user guides at all-guides.com
NOMAD POWER 12V/24V
1 - Set the activation button on the «ON» position.
2 - Connect the male connector on the NOMAD POWER's cigarette lighter
socket.
3 - Connect the cable to your 12V device.
Press the power button for 3 seconds to activate the LED.
Briefly press the button to switch lighting modes (4 available modes: normal,
flash, SOS and OFF).
CAUSES
The NOMAD POWER is discharged.
Internal battery voltage < 11.0V.
Polarity reversal
Short-circuit
Clamps have been left connected to
the battery.
Thermal protection
In 24V mode, the battery voltage is
< 15V.
The voltage output time is 30 s.
REMEDIES
Charge the product (see page 8).
Charge the product.
Check that the clamps are well connected and unplug/
plug back the jumper cable.
Check that the clamps are well connected and unplug/
plug back the jumper cable.
Remove the 2 clamps from the car battery in order to
protect the device.
Disconnect the device for 5 minutes and connect it again.
Press the «24V manual activation» button for 1 s.
Once it's over, the cable must be reconnected.
EN

Publicité