General hints
S Please handle the load cell carefully.
S Use appropriate lifting gear when mounting the
weighing device.
S Do not overload the load cell, not even for a short
time (e.g. due to unevenly distributed supporting
loads).
S If required, use supporting elements (dummies) of the
same height for alignment purposes.
The C16i... is a pendulum load cell designed to automati
cally restore the mounting construction to a stable initial
position in the case of a lateral displacement of the load
introduction (= skewing of the load cell). The maximum
permissible lateral displacement or skewing (see chap
ter 8 "Dimensions") must not be exceeded, otherwise the
load cells or load introduction parts might be damaged.
The easiest and most common solution for this problem
are the appropriate stops on the mounting construction
(weighing platform) which must be carefully adjusted
within the specified values.