PP
8.1 Replacing the wire feed roll
8.2 Replacing liner in torch neck
1
Torch neck
2
Nut
3
Inlet nozzle
Fig. 7
Replacing liner in torch neck
Fig. 6 Feeding in the wire on page EN-10
NOTE
• Required tools, crosstip screwdriver.
• Make sure that the wire feed roll complies with the diameter of the
inserted wire electrode.
1 Lift off clamping cap (2) and swing out seat clamp (7) .
2 Lift off the flat-head screw (3) using the crosstip screwdriver and lift it off
together with the fixing plate (4) .
3 Pull wire feed roll off the seat and replace it.
NOTE
• Ensure tight fit of the wire feed roll in the seat.
4 Swing in seat clamp (7) and attach clamping cap (2) .
1
2
8
4
Clamping cap
5
Counter nut M3
6
Seat clamp
1 Remove torch neck (1) from torch seat (7) by unscrewing the nut (2).
2 Lift off clamping cap (4) and swing out seat clamp (6) laterally.
3 Unscrew counter nut (5) from the inlet nozzle (3) .
8 Maintenance and cleaning
3
7
7
8
4
5
6
Torch seat
Liner (plastic)
EN - 13