4.2
Check the generating set is in a good general condition (bolts, hoses)
Inspect the entire unit before start-up and after each use to prevent any faults or damage.
1.
Check that the unit is clean, in particular the air intake zones (engine air intake, air vents, air filter, etc.).
2.
Check all of the unit's pipes and hoses to ensure they are in good condition and that there are no leaks.
Pipes or hoses must be replaced by a specialist technician. Please contact your nearest agent.
3.
Tighten any loose bolts.
The cylinder head bolts must be retightened by a specialist technician. Please contact your nearest agent.
4.3
Checking the engine oil level and topping up
1.
If the unit has been used, leave to cool for at least 30 minutes
2.
Remove the oil dipstick/filler plug (A2-B1) by unscrewing it, and wipe the dipstick.
3.
Insert the oil dipstick/filler plug in the filler neck (B2) without tightening it, then take it out again.
4.
Visually check the level: it must be between the upper limit (B3) and lower limit (B4) on the dipstick.
If the oil level is too low: open the oil filler cap, use a funnel to top up the tank (using oil that complies with the specifications in the
manual), then screw the oil filler plug back in.
If the oil level is too high: drain some of the oil into a suitable container.
5.
Check the level again before screwing the oil dipstick/filler plug back in fully.
6.
Check that there are no oil leaks, and wipe away any traces of oil with a clean cloth.
4.4
Checking the fuel level and topping up
1.
Fill up when the unit is switched off and the engine cold.
2.
Unscrew the fuel tank cap (A3).
Do not remove the screen filter (
3.
Visually check the level of fuel.
4.
If necessary, fill the fuel tank using a funnel, taking care not to spill any fuel.
Do not overfill the tank; there should not be any fuel in the filler neck.
5.
Carefully tighten the fuel tank cap.
6.
All traces of fuel should be wiped off with a clean cloth.
4.5
Starting the generating set
Once the daily checks have been performed, and having read the instructions and safety regulations carefully:
If the outdoor temperature is above 0°C:
1.
Open the fuel tap (A5) to "I".
2.
Check that the air filter is in the normal position for use
(D1)
3.
If the generating set is cold, move the choke control (A8)
to position "I".
4.
Move the switch (A7) to "ON" or "I".
5.
Slowly pull the starter-recoil reel handle (A9) until there
is some resistance, then let it return gently.
6.
Then pull the starter-recoil reel handle quickly and
sharply until the unit starts.
If the unit does not start, wait one minute before repeating the
process no more than three times.
4.6
Using the electricity supplied
1.
Allow the unit speed to stabilise and the temperature to rise (approx. 3 to 5 min.).
2.
If the choke (A8) was used, return it gradually to its original position.
3.
Connect the equipment to be used to the electrical sockets (A11) on the unit.
4.
Place the voltage selector (A10) in the position corresponding to the voltage you need to use (115V or 230V).
4.7
Switching the generating set off
1.
Disconnect the equipment used, taking care to close the cover for the unit's electrical sockets (A11).
2.
Allow the unit to run idle for 1 or 2 minutes.
3.
Set the switch (A7) to "OFF" or "O ": the unit will shut down.
4.
Close the fuel tap (A5).
5.
Ensure the unit is properly ventilated and to avoid any risk of fire, wait for it to be fully cool before covering it and storing it.
Even when the unit is turned off, the engine continues to give off heat.
As a safety measure, maintenance should be performed on the generating set regularly and carefully by people who have the
necessary experience and are equipped with suitable tools, in respect of current regulations. The maintenance operations to be
carried out are detailed in the maintenance table. The interval for this is supplied as a guide and for generating sets operating with
fuel and oil which conform to the specifications given in this manual. The maintenance intervals can be shortened depending on the
generating set's operating conditions and requirements. It is important to note that the warranty shall not be valid if generating set
maintenance has not be performed correctly.
5.1
Reminder of use
Ensuring maintenance is performed regularly and correctly will guarantee safety and performance. The oil, filter elements and,
where present, the spark plug, are consumables which must be in good condition for the unit to operate correctly. Replace
them regularly as often as is needed (the reference for ready-to-use maintenance kits is given in the table of technical
specifications where applicable). The warranty becomes void in the event of failure to respect the maintenance recommendations.
For any questions about a special operation, please contact your nearest agent who will advise and help you.
1144_EN
A4
) when topping up.
If the outdoor temperature is below 0°C:
1. Open the fuel tap (A5) to "I".
2. Place the air filter in the "low temperature" position (D2).
3. Move the choke control (A8) to position "I".
4. Move the switch (A7) to « ON » or « I »
5. Slowly pull the starter-recoil reel handle (A9) until there is some
6. Then pull the starter-recoil reel handle quickly and sharply until the
17/26
resistance, then let it return gently.
unit starts.
If the unit does not start, wait one minute before repeating the process no
more than three times
Section 5. Generating set maintenance
2022-08-17