Télécharger Imprimer la page

Kohler WELDARC 180 DE Manuel D'utilisation Et D'entretien page 26

Publicité

5.3.4
Cleaning the welding set
To ensure it continues to run correctly, the unit must be cleaned regularly. If the unit is installed inside, always check that the
installation is clean and in good condition. If the unit is being used outside (building sites, dusty, muddy or densely wooded areas,
corrosive environment, etc.), it must be cleaned more frequently.
Use of water sprays or high pressure cleaning equipment is prohibited as this may seriously damage the unit.
1.
Use a brush to gently clean the engine air intakes and outlets and, if present, the spark arrester.
2.
Clean the unit with a sponge and water mixed with a mild detergent (car shampoo, for example), then rinse with fresh
water to remove all traces of the cleaning product.
A cleaning foam may be used and wiped off using a soft, absorbent cloth. Stubborn stains may be removed using a suitable solvent (white
spirit or equivalent) and wiped off using a soft, absorbent cloth.
3.
Check the general condition of the unit (no leakage, tightness of nuts and bolts, connections and hoses, etc.)
4.
Apply an anti-rust product to damaged areas, change defective parts and damaged labels if necessary.
Only use original parts and consult an agent if necessary.
6.1
Transport and handling conditions
The unit should be handled gently and sudden movements should be avoided. Ensure that the place where it is to be stored or used is
carefully prepared beforehand. Before any fixed installation on a trailer or inside a vehicle, consult one of our approved agents.
Before transporting the unit, take the following necessary precautions:
1.
Check that the routes to be used are smooth and drivable. If it proves necessary to use uneven roads, drain the fuel into a
container before setting off.
2.
Check that the bolts are correctly tightened, close the fuel tap (if fitted) and disconnect the battery (if fitted).
3.
The unit should always be transported in its normal operating position; never lay it on its side. Ensure that the unit cannot
fall from the vehicle carrying it, but without exerting too much force (risk of damaging the unit).
6.2
Storage conditions
This procedure for storing the unit or protecting it over the winter must be respected if it is not used for a period of up to 1 year. For
longer periods of storage, it is recommended to contact your nearest agent or to start up the unit for a few hours every year,
ensuring that the storage procedure is respected afterwards.
1.
Start the unit and allow it to operate until it runs out of fuel.
2.
Replace the fuel filter (A18-C1).
The fuel circuit will drain, ensuring that the unit remains in good condition.
3.
First disconnect the red cable (+) then the black cable (-) from the battery (A2), .
4.
Top up the oil.
5.
Replace the air filter (A19).
6.
Clean the unit and cover it with a protective cover.
7.
Store it in its normal position, in a clean, dry and well ventilated area.
7.1
Diagnostics for minor faults
The generating set...
Does not start
Stops
Does not function normally
(noise, smoke, etc.)
Does not supply electrical
current
1071_EN.docx
Check that:
The checks before starting
have been performed.
YES
The battery is correctly connected
and charged.
YES
The devices to be used have not been
connected prior to starting.
YES
The oil level is correct.
YES
The fuel level is correct.
YES
Maintenance has been correctly
performed on the generating set
components.
YES
Have the generating set checked by one
of our agents.
Tripped circuit breaker(s).
YES
The connected devices and their power
cords are not faulty.
YES
Have the generating set checked by one
of our agents.
Section 6. Transporting and storing the welding set
NO
Install the battery; replace it with a new battery
NO
Disconnect the devices then try to restart the
NO
NO
NO
Perform maintenance on the generating set in
accordance with the recommendations
NO
Check the capacity of the generating set and
NO
Try with another device and another power
NO
22/66
Section 7. Repairing minor faults
Solutions to be applied:
Perform the checks.
if necessary.
generating set.
Top up with oil.
Fill up with fuel.
press the circuit breakers.
cord.
*France : 0.806.800.107 (prix appel)