TROUBLE SHOOTING GUIDE CHECKLIST
NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR
PRODUCT WITH THE POWER CONNECTED. DON'T JUST UNSCREW
THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER FROM
THE RECEPTACLE.
TROUBLE
PROBABLE CAUSE
Switch is off position
Motor does
Blown fuse
not run.
Tripped breaker
Disconnected plug
Corroded plug
Float stuck
Defective switch
Defective motor
Improper voltage
Motor runs
Pump may be airlocked
but no water
is delivered.
Pump discharge head too high
Clogged inlet/impeller
Improper voltage
Pump does
Pump may be airlocked
not deliver to
full capacity.
Pump discharge head too high
Clogged inlet/impeller
Defective switch
Pump does
Missing check valve
not shut off.
Clogged check valve in
open position
Float obstruction
TO THE END CONSUMER
If you have any problems with the product, before advising the store, where you've
purchased the pump, please contact us at 514 337-4415 , and ask for our sales
department, and they will be pleased to help you with any questions you might have,
concerning your installation.
6
FOR INFORMATION | TEL : 514.337.4415 | FAX : 514.337.4029
ACTION
Turn switch to on position
Replace
Reset
Re-install
Clean
Check movement
Replace
Replace
Check voltage
Check drilled hole in discharge pipe
Wrong pump selection (over 20')
Clean
Check voltage
Check drilled hole in discharge pipe
Wrong pump selection (over 20')
Clean
Replace
Install valve
Clean debris
Check for movement