APPLICATION :
 Designed for a permanent installation for
homes and cottages application.
 To pumping where the total head
requirements do not exceed 15 feet,
including pipe friction losses.
Capacity :
     
5'
5400
10'
4000
15'
2100
20'
250
Friction loss in pipe
not included.
We recommend that you install your pump in a clean and dry location
STEP 1
where there is adequate room for servicing at a later date. Protection from
freezing temperatures and good ventilation should be considered as well,
to provide the pump an environment for long life.
Friction lossees in the discharge pipe must be taken into consideration
when many elbows and fittings are installed in the discharge line. Each
elbows and fittings must be considered as 1 feet of head.
Never run the pump dry. Damage to the seal may occur.
THE RUN OF THE PIPE FROM THE CHECK VALVE MUST NEVER BE
SLOPING DOWNWARD EXCEPT AT THE FINAL CONNECTION TO THE
EXISTING WASTE OR DRAIN LINE.
For a new installation, install your sewage basin in the excavation you
STEP 2
have provided in the basement floor of your home. Connect the necessary
piping from your shower trap, toilet, etc., to the inlet of your sewage basin,
with the proper pipe and fittings (see diagram).
Cut a lenght of 40'' to 42'' of 2'' ABS/DWV pipe. Cement the 2'' ABS/DWV
STEP 3
male adaptor to 2'' slip to end this pipe.
With your drill, make a 1/4'' hole in the adaptor previously glued. This hole
STEP 4
will prevent any air locking wich might occur.
Screw the pipe with the male adaptor into the 2'' discharge opening in the
STEP 5
pump. Lower pump with piping attached into the sewage basin. Make sure
that the pump is as close as possible to the centre of the basin. Adjusting
the pump in centre of basin will keep mechanical float switch from rubbing
on side of basin.
FOR INFORMATION | TEL : 514.337.4415 | FAX : 514.337.4029
US GPH
US GPH
US GPH
US GPH
INSTALLATION STEPS
see typical installation diagram in page 4
FEATURES :
 Vortex designed impeller made from
cast iron.
 Rugged cast iron pump body.
 Stainless steel mechanical rotary type
motor seal.
 2'' NPT pump discharge.
 Thermal and overload protection.
 Mechanical type float switch, 15A.
 1/2 HP, 115VAC, 60Hz, 9A,
(18A when start.)