GENERAL DESCRIPTION
The chargers ENERGY 123, 124 and 126 are designed to charge lead acid batteries with liquid electrolyte, nominal vol-
tage from 12V, and with capacity according to the following table:
ENERGY 123
ENEGRY 124
ENERGY 126
OPERATING MODE WITH TESTER FUNCTION
When it is not connected to the mains supply, this charger is a battery tester. It lets you know the state of the battery.
The integrated voltmeter informs you:
•
<12.3V : battery to be charged
•
between 12.3 and 12.6V : middle charge
•
>12.6V : charged
CONNECTION IN CHARGER FUNCTION
Preliminary precautions
•
For indoor use, with good ventilation.
•
Remove the battery caps if there is, and check the level of liquid. If it is not correct, filled up with distilled water.
Clean well the battery terminals.
•
Check if the battery capacity and voltage are compatible with your charger.
Connection and disconnection
•
Disconnect from the battery all electronic system during the charge (Do not charge the battery when it is connected
to the vehicle as it may damage the vehicle's on-board electronics).
•
Connect the clamps (+ red, - black) to + and - battery terminals, making sure you get a good electric contact,
respecting the following order.
◦ Connect first the battery terminal not connected to the chassis of the vehicle.
◦ Then connect the other connection to the chassis remote from the battery and any fuel line.
◦ At last, plug in your charger to 230 V 50/60 Hz mains supply.
After charging, disconnected the battery charger from supply mains. Then remove the chassis connection and the
battery connection, in this order.
Control of the charge process
•
You should observe a variation of the voltage indicated by the voltmeter. When this voltage is over 14,8 volts, the
battery has reached its full charge state. The charge must then be stopped.
•
Do not connect the charger more than 24 hours on a battery.
8
All manuals and user guides at all-guides.com
ENERGY 123, 124, 126
facility. Do not dispose of in domestic waste.
recycling process by contributing to a global system of sorting,
collecting and recycling of households' packaging waste.
recommendations
Current
2A DC
3A DC
4A DC
Minimum
Maximum
8 Ah
30 Ah
10 Ah
45 Ah
15 Ah
60 Ah
EN