11. Technical Specifications
Explanatory notes on the specifications on page 3.
Changes due to technological progress reserved.
P
= Rated input power
1
P
= Power output
2
n
= No-load speed
1
I
= Current at 120 V
120 V
D
= Max. drilling diameter in concrete with
1
impact masonry bits
D
= Max. drilling diameter in concrete with
2
impact core cutters
s
= Maximum impact rate
max
W
= Single impact force
C
= Number of chisel positions
m
= Weight without mains cable
The technical specifications quoted are subject to
tolerances (in compliance with the relevant valid
standards).
Emission values
These values make it possible to assess the
emissions from the power tool and to compare
different power tools. Depending on the operating
conditions, the condition of the power tool or the
accessories, the actual load may be higher or lower.
For assessment purposes, please allow for breaks
and periods when the load is lower. Based on the
adjusted estimates, arrange protective measures
for the user e.g. organisational measures.
Vibration total value (vector sum of three directions)
determined in accordance with EN 60745:
a
= Vibration emission value (hammer drilling
h, HD
into concrete)
a
= Vibration emission value (chiselling)
h, Cheq
K
= Uncertainty (vibration)
h,HD/Cheq
Typical A-effective perceived sound levels:
L
= sound-pressure level
pA
L
= acoustic power level
WA
K
, K
= uncertainty
pA
WA
Values measured as per EN 60745.
L
= Measured acoustic power level as per
WA(M)
2000/14/EG
L
= Guaranteed acoustic power level as per
WA(G)
2000/14/EC
During operation the noise level can exceed
80 dB(A).
Wear ear protectors!