Alignment
After set up of the FL 270VA-Tracking and receiver FR 77-MM Tracking switch on both the laser and the
receiver. After the self-levelling process of the laser is completed press button
The tracking function is activated and the blue LED at the receiver is
blinking.
After reaching "on-grade" the blue LED at the receiver stops blinking and the green LED lights perma-
nently.
This indicates that the tracking process is completed.
The receiver FR 77-MM returns into normal reception mode.