water. In case of eye contact rinse thoroughly for at least
10 minutes and immediately seek medical attention.
Warning! To reduce the risk of fi re, personal injury, and
product damage due to a short circuit, never immerse your
tool, battery pack or charger in fl uid or al-low a fl uid to fl ow
inside them. Corrosive or conductive fl uids, such as
seawater, certain industrial chemicals, and bleach or
bleach containing products, etc., Can cause a short circuit.
SPECIFIED CONDITIONS OF USE
The Battery-lamp is intended to be used light independent
use away from mains supply.
Additionally the charger can charge the specifi ed
Milwaukee battery packs.
Do not use this product in any other way as stated for
normal use.
MAINS CONNECTION
Connect only to single-phase AC system voltage as
indicated on the rating plate. It is also possible to connect
to sockets without an earthing contact as the design
conforms to safety class II.
Please use IP54 degree's connection at least when 250V
UK plug connect to the supply.
CHARGING TIME
Battery Cat. No.
Volts
M18B
18 V
M18B2
18 V
M18BX
18 V
M18B4
18 V
M18B5
18 V
M18B6
18 V
M18B9
18 V
M18HB3
18 V
M18HB4
18 V
M18HB5.5
18 V
M18HB8
18 V
M18HB12
18 V
LI-ION BATTERIES
The rechargeable batteries are partially charged. The LED
on the battery indicates the state of charge.
If it is not used for long periods, the rechargeable battery
will switch to the non-operative state.
When fully discqharged the rechargeable battery switches
off automatically (depth discharge not possible).
Under extreme circumstances, the internal temperature of
the battery could become to high. If this happens, the
battery will shut down.
Place the battery on the charger to charge and reset it.
The state of charge can be read by pressing the button on
the rechargeable battery. The battery can be left in the
electric tool while the reading is taken but it must be
switched off at least one minute beforehand (otherwise the
display will be inaccurate). The number of LEDs illuminated
indicates the state of charge. A fl ashing LED indicates a
max. power reserve of 10%.
As a general principle, if the electric tool should fail to work
after inserting the rechargeable battery, then the battery
should be plugged into the charger. The displays on the
battery and charger will then provide information about the
condition of the battery.
In low temperatures work may continue at reduced output.
470 426 - M18POALC.indd 19
470 426 - M18POALC.indd 19
All manuals and user guides at all-guides.com
Capacity
Charging Time
approx.
≤ 1.5 Ah
30 min
≤ 2.0 Ah
40 min
≤ 3.0 Ah
60 min
≤ 4.0 Ah
80 min
≤ 5.0 Ah
100 min
≤ 6.0 Ah
120 min
≤ 9.0 Ah
180 min
≤ 3.0 Ah
40 min
≤ 4.0 Ah
40 min
≤ 5.5 Ah
90 min
≤ 8.0 Ah
130 min
≤ 12.0 Ah
210 min
CHARGING CHARACTERISTICS
After inserting the battery into the reception of the charger
the battery will automatically be charged (red control lamp
is illuminated continuously)
When a hot or cold battery pack is inserted into the charger
(fl ashing red lamp), charging will begin automatically once
the battery reaches the correct charging temperature
(0°C...60°C). The max. charging current is fl owing when
the temperature of the Li-Ion-battery is between 5°C and
40°C.
Charging time varies depending on the battery
temperature, charge needed and the type of battery pack
being charged.
Once the battery is fully charged, the LED on the charger
changes from red to green.
Remove the battery pack from the tool for charging when
convenient for you and your job. Milwaukee batteries do
not develop a "memory" when charged after only a partial
discharge. It is not necessary to run down the battery pack
before placing it on the charger.
As a general practice, it is best to unplug battery chargers
and remove batteries when not in use. No battery pack
damage will occur, however, if the charger and battery pack
are left plugged in.
If the LED fl ashes alternately red/green, then the
rechargeable battery is either not fully pushed in or there is
a fault with the battery or charger. Take the charger and
battery out of use immediately for safety reasons and have
them inspected by a Milwaukee customer service centre
LIGHT INDICATORS
Continuous red
Continuous green
Fast fl ashing red
Flashing red/
green
BATTERIES
Battery packs which have not been used for some time
should be recharged before use.
Temperatures in excess of 50°C (122°F) reduce the
performance of the battery pack. Avoid extended exposure
to heat or sunshine (risk of overheating).
The contacts of chargers and battery packs must be kept
clean.
For an optimum life-time, the battery packs have to be fully
charged, after used.
To obtain the longest possible battery life remove the
battery pack from the charger once it is fully charged.
For battery pack storage longer than 30 days:
Store the battery pack where the temperature is below
27°C and away from moisture
Store the battery packs in a 30% - 50% charged condition
Every six months of storage, charge the pack as normal.
Charging
Charging is complete
Battery is too hot/cold -
Charging will begin when
battery reaches correct
charging temperature
Damaged or faulty battery
pack