Also consider emptying the hoses placed outdoors to prevent frost damage; open any water taps that may
be installed.
• Carry or transport the clear water pump only by the carry handle. Never hold it by the hose, the float switch or even
the mains cable.
• After operation or emptying, a small amount of water may be retained in the clear water pump. Therefore, use a
suitable support when storing or transporting it in a vehicle.
11. Maintenance and Cleaning
The clear water pump has no parts that require maintenance by you. Therefore, never open or disassemble it. Main-
tenance or repair and opening of the clear water pump in this context must only be performed by a specialist or
specialist workshop.
Before cleaning, disconnect the clear water pump from the mains voltage; pull the mains plug from the mains socket.
To clean the outside of the clear water pump, a dry, soft and clean cloth is sufficient. If required, flush the outside with
clear water.
Any contamination of intake openings may be removed under running water (e.g. garden hose). The clear water pump
inside may be flushed with running water as well by removing the hose and any connection piece.
Dry the clear water pump and the mains cable before storing it.
Never use any aggressive cleaning agents, cleaning alcohol or other chemical solutions, since these may
damage the casing or even impair function.
12. Troubleshooting
With this clear water pump, you purchased a product built to the state of the art and operationally safe. Nevertheless,
problems or errors may occur. Therefore, observe the following information about troubleshooting.
Clear water pump does not take in water
• Open any present shut-off valve on the pressure-side, since air cannot escape from the hose or in the pump. Move
the pump back and forth a little. If required, fill water into the clear water pump or the hose. Briefly pull the mains
plug from the socket and plug it back in.
• Clean intake openings (disconnect clear water pump from the mains voltage first!).
• The water level is too low or air is sucked in as well.
The clear water pump does not start up or stops in operation
• Check the power supply or the circuit protection and the FI protection switch. If the FI protection switch has trig-
gered, disconnect the clear water pump from the mains voltage and check for damage (e.g. mains cable).