 Carry out a regular visual inspection.
Make sure the pump is not damaged.
Check the electrical cable, the plug, the
float switch and the float cable for
damage too. If you discover damage, you
must take the device to your supplier or
an accredited professional. Never attempt
to carry out repairs yourself and never
open the pump!
 Regularly check that the float switch is
working effectively, particularly if you
have set the pump to work automatically
(every 3 months). Regularly remove
residues from the float with clean water.
Turn the pump upside-down, open the
side-panel with a pin or similar and
remove (see diagram). Take the pin and
float out and clean the float and the
magnet. Prevent damage or incorrect
assembly and do not remove the float
from the pin!
 Regularly check whether any dirt (fibres, residues) has accumulated around the
blade. Remove it if this is the case by cleaning the pump with clean water. If you
cannot do so, take the pump to your supplier or to an accredited professional to
open the device and remove the residue.
 If you regularly use the pump at different locations, you must rinse with clean
water (inside and out) after each use.
 Keep the base of the well (or the tile on which the pump is positioned) free from
mud and residue.
 Ensure that the pump does not freeze. Before winter sets in, run the pump dry
and store it in a frost-free location.
Defects – causes – solutions
Defects
Pump does not
start
Pump runs but
does not pump
water
Causes
No electricity
-
Overheating safeguard
-
activated
Pump is stuck
-
Inlet openings are
-
clogged
Water drainage pipe is
-
bent or hose is blocked
Air around the blade
-
Solutions
Check electrical supply
-
See: overheating safeguard.
-
Clean float and float axle
-
Clean them
-
Straighten the hose or
-
remove the blockage
Switch the pump off and
-
move it from side to side.
Wait until the air has escaped
and switch on again