Technical specifications
Type
Connection voltage
Power consumption
Cap. max.
Class of insulation
Max. supply depth
Max. submersion depth
Max. water temp.
Hose connection
Max. size of
contamination
Residual water
(Manual)
Start level (auto-
setting)
Stop level (auto-
setting)
Noise level Lpa
Cable
Cable length
Dimensions
Weight
Safety recommendations
Before using your new pump, check it, including cord and plug, for
any visible damage. Do not use a damaged pump, but send it back
to your dealer for replacement.
For safety reasons, your submersible pump must always be
connected to an earthed socket that has been installed according to
national regulations, forms part of an electricity network that is
equipped with a fuse of at most 16 Amp and has an earth leakage
circuit breaker (nominal voltage ≤30 mA).
Check your pump, electrical cable, plug and socket before each use.
Do not use if the device is damaged and have this damage repaired
by an accredited electrician. The cable is an H05RN-F 3G 1.00mm²
type.
Ensure that electrical connections stay dry at all times. Do not touch
them with wet hands.
Flow Pro 550CW
230V – 50Hz
550W
11.000 l/h
IP68
9m
5m
40°C
25mm – 1" – 32mm - 1½"
3mm
5mm
140mm
30mm
≤70dB(A)
H05RN-F 3G 1.00mm²
22x16x31
22x18,5x26
4 + 1 kg
13
Flow Pro 550DW
230V – 50Hz
550W
11.000 l/h
IP68
7m
5m
40°C
25mm – 1" – 32mm - 1½"
16mm
16mm
140mm
30mm
≤70dB(A)
H05RN-F 3G 1.00mm²
21x16x33
22x18,5x28,5
4 + 1 kg