Télécharger Imprimer la page

Efco TC 002 Mode D'emploi page 18

Publicité

6.
Unpacking and handling
When unpacking or transporting the device, always hold the lower side to lift it.
Never lift it by holding the cable or the mains connector.
Before putting the device into service, remove all packaging material from it.
7.
Installing and connecting to electricity
Set up the kiln in a well ventilated room, away from other sources of heat and on a fire-proof,
heat-resistant surface. Remove all inflammable material around the kiln. Do not obstruct any
ventilation holes. Due to the high temperatures inside, it is inevitable that correspondingly heat
will radiate from the device, especially at the door. Place a heat dissipator or a ceramic plate
under the door opening. Do not operate the kiln in the vicinity of easily inflammable or explosive
substances. If the unit is operated with a UK plug, its capacity is 13 A, due to the fuse in
the UK plug. If more power is required, the unit must be connected directly to the mains with a
fuse for 16 A.
Do not place the temperature controller on the kiln.
Choose a place for the controller, where you can quickly switch it off or disconnect it from the
mains in the case of an emergency.
8.
Putting the controller into service
The controller may not set a temperature range above the allowable maximum temperature of
your kiln. Please ask the manufacturer of your kiln, if you do not know the maximum temperature
of your device.
Plug the kiln into the socket of the controller.
Remove the protective cardboard tube and connect the temperature sensor to the sensor
connector of your kiln. Connect the controller to the 230 Volt socket earthed in accordance with
the regulations.
9.
Operation
Operation of the temperature controller
The temperature controller serves to control the heating-up temperature of your kiln.
Introduce the temperature sensor supplied with the controller into the socket provided for the
sensor on the back of the kiln.
After switching on the controller first shows all display segments, then briefly the current software
version and then switches to the operating mode.
In run mode, the controller goes to the last selected program and continues this, if the program
was not completed.
Complete the program or end by pressing the start/stop button until the display
displayed.
The regulator has two modes of operation:
a.) As a temperature controller (Reach temperature and hold).
b.) operating as a firing cycle controller, it can run 15 programs
Ramps in each program.
stOP
is
(CY01 to
cY15) with up to 45

Publicité