Code F1 displayed
Code F2 displayed
Code F3 displayed
Code F4 displayed
Code F5 displayed
Code F6 displayed
Code F7 or F8 displayed
*For models with FSAK-002 detachable battery, if code F1 displayed, unplug or turn off the battery,
or connect to DC12/24V/AC100-240V(using the adapter) power supply to power the compressor
and battery in time to avoid long-term micro-current draining the battery.
9. WARRANTY
If the device gets malfunctional, limited warranty will be provided for 1 year from the date of
purchase, except following situations:
• Contrived damage.
• Damage caused by force majeure such as earthquake, conflagration, etc.
• Damage from inappropriate use or violating this instruction.
• Damage or malfunction caused by disassembling.
10.TECHNICAL INFORMATION
MODEL
RATED VOLTAGE
RATED POWER
CAPACITY
NOISE
TEMPERATURE SETTING RANGE
CLIMATE CATEGORY
DIMENSIONS (L*W*H)
NET WEIGHT
*Due to product improvement, the technical information might be different from actual
information, please refer to the rating label on the product.
• Possible cause: low voltage to fridge.
Adjust the battery protection from High to Medium or from Medium to Low.
• Possible cause: condenser fan is overloaded. Disconnect power to fridge for
5 minutes & re-start. If the code shows again, contact manufacturer for service.
• Possible cause: the compressor starts too frequently. Disconnect power to
fridge for 5 minutes & re-start. If the code shows again, contact manufacturer
for service.
• Possible cause: compressor not kicking in. Disconnect power to fridge for 5
minutes & re-start. If the code shows again, contact manufacturer for service.
• Possible cause: overheating of the compressor & electronics. Disconnect
power to fridge for 5 minutes & re-start. If the code shows again, contact
manufacturer for service.
• Possible cause: no parameter can be detected by the controller. Disconnect
power to fridge for 5 minutes & re-start. If the code shows again, contact
manufacturer for service.
• Possible cause: temperature sensor is faulty. Contact manufacturer for service.
DC12/24V or AC100~240V(using dedicated adapter) or Solar(12~50V)
631*378*375 mm - 24 7/8*14 7/8*14 3/8 inch
12.8kg /28.2lb (not including battery)
VFT30
60W
27.8L/0.98 cu.ft.
≤45dB
-20~20°C (-4~68°F)
T/ST/N/SN
ENG