2. Gas Tank valve is OFF.
3. Disconnect Gas line.
FOR YOUR SAFETY:
• Do NOT touch or move heater for at least 45 minutes after use.
• Reflector is hot to the touch.
• Allow reflector to cool before touching.
To enjoy years of outstanding performance from your heater, make sure you perform
the following maintenance activities on a regular basis:
Keep exterior surfaces clean.
1. Use warm soapy water for cleaning. Never use flammable or corrosive
cleaning agents.
2. While cleaning your unit, be sure to keep the area around the burner and pilot
assembly always dry. Do not submerge the control valve assembly. If the gas
control is submerged in water, do NOT use it. It must be replaced.
a. Keep the appliance area clear and free from combustible materials,
gasoline and other flammable vapors and liquids.
b. Do not obstruct the flow of combustion and ventilation air.
c. Keep the ventilation opening(s) of the cylinder enclosure free and clear
from debris.
3. Air flow must be unobstructed. Keep controls, burners, and circulating air
passageways clean.
CARE AND MAINTENANCE
Visually checking portions of the hose assembly located within the confines of the
heater post. Inspect the entire hose assembly at least annually, disassembling the
reflector and burner. Inspect the hose assembly for evidence of excessive abrasion,
cuts, or wear. Suspected areas should be leak tested.
Then assembling the reflector and burner again following with step 5 and 6.
Signs of possible blockage include:
Gas odor with extreme yellow tipping of flame.
The heater does NOT reach the desired temperature.