16. Screw gas hose and regulator to propane cylinder (not included). Do not cross-
thread.
Use a standard 20 lb. propane cylinder only (approximately 12.2 in. / 31cm. in
diameter and 17.9 in. / 45.5cm high).
Every part of the heater shall be secure against displacement and shall be
constructed to maintain a fixed relationship between essential parts under normal
and reasonable conditions of handling and usage. Parts not permanently secured
shall be designed so they cannot be incorrectly assembled and cannot be
improperly located or misaligned in removing or replacing during cleaning or
other servicing.
Use this heater only with a propane vapor withdrawal supply system. See chapter 5
of the standard for storage and handling of liquefied petroleum gas, ANS/NFPA
58. Your local library or fire department should have this book. Storage of an
appliance indoors is permissible only if the cylinder is disconnected and removed
from the appliance. A cylinder must be stored outdoors in a well-ventilated area
out of the reach of children. A disconnected cylinder must have dust caps tightly
installed and must not be stored in a building, garage or any other enclosed area.
The maximum inlet gas supply pressure: 250 psi /1750 kPa. The minimum inlet
gas supply pressure: 5 psi /35kPa. Manifold pressure with regulator provided:
11inch W.C/ 2.74 kPa.