Télécharger Imprimer la page

TECE SH-DTP Guide D'utilisation page 74

Publicité

no
bAS
Default value: no
Values: YEs /no
E
d1SP
Default value: no
Values: YEs /no
20
CAL1
Default value:
0°C of offset
Values:
between -5.0°C and 5.0°C
74
"basic navigation" configuration
➤ "YEs": activation of function, restrict to comfort and off mode
bAS
04
➤ "no": no activation
no
bAS
Room temperature display
05
➤ "YEs": remote displays measured temperature
5
➤ "no": thermostat displays set point temperature
Calibration of internal room sensor
This menu is only displayed if parameter rEGU (#30) is set with "Air" or "FLr" or "FLL".
Calibration must be done after a given order has been operating for a day.
Place the thermometer in the middle of the room at about 1.5 m above the floor.
Record the temperature shown after 1 hour.
06
Enter the reading on your thermometer turning button
20
8
C
CAL1
°
.
Important note:
➤ A large temperature deviation may indicate an inappropriate installation of
the thermostat. If the temperature difference is too big, this could mean your
thermostat was not installed properly e.g. in the right place.
➤➤ Open window function should not de trigged in any cases if user changes offset
value. This function will be restarted after user validation.
E
04
5
04
06
8
C
°
.
The setting is validated with key
E
05
d1SP
5
no
05
d1SP
(step of 0.1°C).
.
GB

Publicité

loading

Ce manuel est également adapté pour:

77420055