There are 3 different templates predefined in the device (see below) or a"day by day" programming and a "save" menu:
Type
Mo Tu We Th Fr Sa Su
Mo Tu We Th Fr
Template
Day
SAUE
"Save"
7.2 Interval selection
User will be able to define four intervals per day. "t1" to "t4" corresponds to "time 1" to "time 4".
Each interval will have its own temperature set point.
Set point value is higher than ECO temperature set point and its maximal value corresponds to 30°C.
When user starts program edition, he can select interval "t1" (time 1), "ECO" to define reduced set point or select "SAVE"
to finish configuration without any interval.
After edition of the first interval "t1", user can select :
interval "t1" for modification,
interval "t2" for edition of a new interval,
"ECO" to define reduced set point or
"SAVE" to save program with only one interval.
t1
Ed t
Important points:
➤ Without any edited "comfort" interval, thermostat will apply during all day ECO temperature set point.
➤ ECO/reduced set point value ca be modified in "program edition menu". But, user will be able to modify this value by
going to "reduced/ECO mode" (see paragraph "Working mode description/Reduced mode"). If user changes reduced/
ECO set point, program temperature set point will be updated with this new value.
66
LCD displaying
Sa Su
Mo
Tu
We
Th
Fr
Sa
Su
U
Interval selection: no defined interval
t1
Ed t
Interval selection: 1 defined interval
t2
Ed t
All days of the week will have the same configuration
All days between Monday and Friday will have the same configuration
Saturday and Sunday will have the same configuration
Each day has its own configuration. User will edit selected day
Save edited user program and return to main menu
SAUE
SAUE
Description
Ec
Ed t
o
Ed t
GB
Ec
o