Performance Features
Model
Diameter
Torque
(mm)
(Nm)
RA35F
45
25
Max. area (area = length x breath)
RA35F
2
PVC
10m
8,0m
2
ALU
4,2m
2
WOOD
2
AWNING
11,5m
Carton Contents
Motor (1)
Adjuster pin (2)
Drive adapter safety catch (3)
Square pin (not pre-mounted) (4)
Shaft adapter (5)
Wall bracket (6)
Manual
Remote Control and Wall Clip
INSTALLATION PROCESS SEQUENCE AND STEPS
1. INSTALL DRIVE (INSTALLATION)
2. WIRE UP AND CONNECT DRIVE (MOTOR CONNECTION)
3. SET LIMITS OF SHUTTER (THE REMOTE CONTROL HAS ALREADY BEEN PROGRAMMED).
PLEASE NOTE: SHOULD THE UP / DOWN BUTTON FUNCTION THE WRONG WAY ROUND I.E. AS DOWN / UP BUTTON, WAIT UNTIL
STEP 5 BEFORE CHANGING IT!
4. INSERT SHUTTER ARMOURING (SLATS) AND COMPLETE INSTALLATION.
5. CHANGE FUNCTIONALITY OF REMOTE CONTROL (REVERSE DIRECTION OF MOVEMENT (UP / DOWN) ON THE REMOTE CONTROL
AND PROGRAMME NEW REMOTE CONTROLS).
INSTALLATION
Rough- in or install conduit pipe to the connector box for the electrical
connecting line according to local building and electrical codes.
THE DRIVE IS PREMOUNTED. THE DESCRIPTION IS FOR
CHECKING PURPOSES!
Place the tube drive adapter (6) on the motor and fix the drive
A
adapter with the parts (3).
Fix the square pin with the screws on the motor (4 or 5).
Fully unroll the shutter (a). Remove the shutter material from the
B
tube (b). Remove the manual control (c).
C
Remove the tube.
Push the motor (1) completely into the tube. The limit switch
D
operates only if the drive unit is fully inserted. Ensure that the
adapter ring is pushed fully home. Do not force it or strike it.
Do not damage the tubular motor by drilling!
E
Proceed according to the specific requirements for left-sided (a)
or right-sided (b) operation:
F
Secure the mounting bracket (7) to the wall (use suitable screws
and plugs).
G
Insert the motor (a) into the mounting bracket (7) and secure it.
Make sure the set screws for the limit adjustments are accessible.
Don't return the shutter material to the tube yet!
Speed
Operating
Frequency
Voltage
(rpm)
(V)
(Hz)
15
230
50
Current
Motor
StandBy
input
rating
(A)
(W)
(W)
0,89
230
1,4
A
3
5
B
a
b
C
1
D
E
a
Limit Switch
Operating
Range
time
(U)
(min)
25
4
5
1
4
2
c
F
7
G
7
a
b
6