6 Operation
The measuring sleeves are torch-specific and have different threaded stems:
M8
M6
M10
M10x1
Tab. 7
Adjusting sleeves
1 Screw in the measuring sleeve at the position of the contact tip.
2 Plug on/screw in the adjusting sleeve at the position of the gas nozzle.
6 Operation
NOTICE
Before inserting the torch into the alignment jig, check:
• Whether the correct interface and the corresponding torch are inserted.
• Whether the dust and welding spatters are removed. This might cause wear and reduced test accuracy.
6.1 Quick Control
1 Remove the neck liner and the wire guide.
2 Fasten the change neck torch into the clamping device.
1
Test mandrel
Abb. 8
Quick Control
3 Move the test madrel (1) to the contact tip (2).
The bending angle is correct if the tip of the test mandrel (1) and the contact tip (2) are centered.
6.1.1 Check the alignment.
1 Unscrew or pull out the gas nozzle and remove other torch-specific fittings.
1
Test mandrel
Abb. 9
Checking the Alignment
2 Screw in the measuring sleeve (2) at the position of the contact tip.
The bending angle is correct if the test mandrel (1) fits easily into the bore of the measuring sleeve (2).
EN - 12
WH 455, WH 505/505 TS, ROBO VTS 0/500 TS,
WH 241/242, ROBO VTS 500/500 TS, ROBO VTS 290, ABITIG-WH
WH 650/652
®
350 GC
ABIROB
1
2
1
2
®
W 500 TS
ABIROB
2
Contact tip
2
Measuring sleeve
BAL.0022 • 2019-04-23