TECHNICAL SPECIFICATIONS
WARNING: for technical data refer to the label of charger 9HC180LT
TYPE
Input Volts (VAC)
Input frequency (Hz)
Power (W)
Charging time (with 9HB180LT)
Output Volts (VDC)
Output Amps (A)
WARNING: to reduce the risk of injury or explosion, never burn or incinerate a tool's battery pack even if it is
damaged, dead or completely discharged. When burned, toxic fumes and materials are created.
CHARGER 9HC180LT OPERATION
WARNING: to reduce the risk of injury and property damage use only a provided cable. In a case of loose or damage
of the cable contact Rupes service center.
Voltage
100-120V
220-250V
WARNING: before connect the cable to the electric socket check if the voltage of the electric socket coincides with
the Voltage specified in the label of Li-ION Battery Charger 9HC180LT.
WARNING: charge Rupes Li-ION Battery pack 9HB180LT only in the Rupes Li-ION Battery Charger 9HC180LT. Other
types of batteries may cause personal injury and damage. This tool's battery pack and charger are not compatible
with NiCd or NiMH systems.
When to charge
Charge your battery tool when convenient for you and your job. The Rupes 18V Hybrid tool Battery pack does does not develop
"memory" when charged after only a partial discharge. It is not necessary to run down the battery tool pack before placing it on the
charger.
Use the led lever indication on 18V Li-ION Battery pack 9HB180LT to determine when to charge it:
• Four leds: from 100% to 75% batteries charge
• Three leds: from 75% to 50% batteries charge
• Two leds: from 50% to 25% batteries charge
• One led: from 25% to 0% batteries charge
• One led Blinking: 0% battery charge: the tool does not start.
How to charge
Plug the charger into the power supply socket: the green light will firmly turn on (stand by). Place the battery pack into the seat by
sliding it from the top: the red light will firmly turn on (the battery is charging).
A fully discharged battery pack with an internal temperature in the normal range will charge in 35 minutes.
After charging is complete, the green light will firmly turn on. The charger will keep the battery fully charged if it is left inserted. If the
red light flashes, the battery pack is damaged: contact a Rupes service facility.
Maintenance and storage
WARNING: to reduce the risk of injury, always unplug the charger before performing any maintenance. Never
disassemble the battery pack, the tool or charger. Contact a Rupes service facility for all repairs (refer to "Rupes
WARRANTY").
To reduce the risk of injury and damage, never immerse your battery pack, tool or charger in liquid or allow a liquid to flow
inside them.
Cleaning: Clean out dust and debris from charger vents and electrical contacts by gently blowing with compressed air; wearing
appropriate dust mask taking consideration of the type of material having been worked.
Only use a mild soap solution on a damp cloth to clean the battery tool and charger, keeping away from all electrical contacts.
Other cleaners may contain chemicals that could cause damage to the plastic and other insulated parts. Some of these include
gasoline, turpentine, lacquer thinner, chlorinated cleaning solvents, ammonia, and household detergents containing ammonia. Do
not use flammable or combustible solvents (refer to previous instructions) around battery pack 9HB180LT and charger 9HC180LT.
Charger 9HC180LT
100-240
50/60
95
35 min ± 5%
18
Correspondence between Voltage and plugs