Access to the energy conversion area:
It is essential not to install, repair, start any maintenance on this device under voltage. All energy sources must
be turned off. The batteries must be isolated by the battery disconnect switches according to the standard.
Chargers, alternators, or other energy-generating devices must be turned off, or isolated.
3 I
NSTALLATION
This paragraph is about the installation of the device.
Installation and initial commissioning should be carried out by an electrician or professional installer in
accordance with the standards currently in force (for small crafts the applicable international standards is
ISO13297).
Before any action the installer should read carefully this manual and notify users of the instructions for use
and the safety warnings.
3.1
D
IMENSIONS
Fix the inverter vertically, (cables and wires down). Non- respect of this position can lead to a reduction of
power, and a loss of degree of IP.
Fixing of the inverter is made by 4 x M6 round head screws (screw head diameter less than 10 mm) see back
view:
Back view
Side view
Bottom view
P 4