8 T
ECHNICAL SPECIFICATIONS
Part Number
DC Input
Voltage
Maximum current
On Mode @ No Load Mode
Off Mode (Remote/Integrated)
Efficiency
Recommended external input fuses
(not included)
Minimum recommended Lead
battery capacity*
AC Output
AC Range
Frequency Selectable
Rated Power
Peak power 3s
Waveform
Recommended external protection
(not included)
Environment
Cooling
Operating temperature
Storage temperature
Relative humidity
Casing
length, height, depth / Weight
Fixing screw (wall)
Protection factor
PCB protection
Communication Ports
Standards
CE declaration of conformity
CE / EMC
CE / Security - Others
Protections
Input
Output
*F
L
OR
ITHIUM BATTERIES DIVIDE THE VALUE BY
KERS12-230/2400
10,5V -16V
240A
300A
200Ah
2400VA/2000W @25C°
2000VA/1800W @40C°
Electric fan controlled in temperature and current
From -20°C to +65°C. Above 65°C switch off
Under Voltage / Over Voltage
Short Circuit / Overload / Over Temperature
T
WO
KERS24-230/2400
21V -32V
120A
30W
20mW
92%
200A
100Ah
220/230/240Vac
50/60Hz
2400VA/2000W @40C°
2000VA/1800W @55C°
3000W@25C°
Pure Sine Wave THD < 3%
GFCI 16A/30mA
From -40°C to +70°C
up to 70% (95% without condensation)
270 x 410 x 130 mm / 6,8kg
4 x M6 round head screws
IP23
Water-repellent varnish (marine environment)
CANBUS
Available on request
EN61204-3
EN60335-1
KERS48-230/2400
42 -64V
60A
100A
50Ah
2400VA/2000W @40C°
2000VA/1800W @55C°
-
automatic restart
P 13