Main precaution
Before handling the inverter KERSINE, please read carefully
this manual.
Precautions regarding electric shocks
Risk of electric shock and danger of death: it's strictly forbidden to
open the inverter under voltage.
Precautions regarding AC-output
Do not connect the AC-output to an incoming AC source or any
other inverter.
The neutral wire of the AC output of this inverter is NOT
connected to the chassis.
The installer or the electrician must follow the standards and the
installation specifics. The neutral to ground link has to be done
once at least in the whole electric installation to ensure people
protection with a proper GFCI.
Precautions regarding accidental earth leaks
Operation without proper grounding may lead to hazardous
situations. The inverter's Protection Earth Terminal (PE) must be
earthed and connected before any other terminal.
Accidental leakage current between phase and earth:
P 16